Parameter Configuration
The ST 630 offers the possibility to change different operating parameters:
(1) kiln output to determine the energy consumption in kW
(2) time interval of USB recording in seconds (s)
(3) temperature unit in °C or °F
These values can be adjusted in the controller's parameter level.
While turning on the controller push the
The controller displays the first available parameter immediately after releasing the
j
key. The display shows „P14-".
Push the
d
and
f
Push the
g
key to show the selected parameter.
This value can be changed with the
After setting all parameters, push the
display gets darker and the controller restarts. The controller is now in operating
mode again and can be used in the usual way.
The ST 630 offers the possibility to change parameter numbers 14, 50 and 60.
The following table describes each parameter:
No.
Function
P14
Output, zone 1 (top zone)
P24
Ouput, zone 2 (top zone)
P34
Output, zone 3 (top zone)
P45
Control relay 1 (e.g. damper/fan)
P49
Control relay 2 (e.g. damper/fan)
50
USB recording interval in s
60
Temperature display in °C or °F
See separate document "Configuration Handbook" for other settings.
keys to select the parameter number.
d
j
Min.
0
0
0
0
0
5
0
* 0 = disabled, 1 = control relay, 2 = fan, 3 = damper
key until "tC.S" is displayed.
j
and
keys.
f
key to save your changes. The controller
Default
Max.
setting
9999
0
9999
0
9999
0
3
0
1
0
300
60
1
0
Remark
1 unit = 0.1 kW
1 unit = 0.1 kW
1 unit = 0.1 kW
*
**
Seconds
0 = °C, 1 = °F
** 0 = disabled, 1 = event 2