is not allowed by the norms.
Once the failing safety device is repaired, in automatic after 1 second, all standard commands
functioning again so radio commands and the automatic closing will be enabled again.
Note 1: during this functioning in hold-to-run mode, in case of damage to the safety strips (or
photocells) the photocells (or safety strips) still work by interrupting the operation
in progress.
Note 2: the stop command is not to be considered a safety command that can be bypassed
in this mode. Therefore, when pressed or damaged, it will not allow any movement
of the gate.
The hold-to-run mode is only an emergency operation which must be activated for a very
short period and with the complete installation at sight so to have a secure and safe control
of the system. As soon as possible however, the failing safety devices must be repaired and
activated.
VISUAL AND SOUND ALARMS
BLINKER
N.B.: This control panel can power ONLY BLINKERS WITH BLINKING CIRCUIT (ACG7072) 24Vdc
and 20W.
PRE-BLINKING
DIP 5 OFF => motor and blinker start simultaneously.
DIP 5 ON => blinker starts 3 seconds before the motor.
BUZZER
It has the task to signal the intervention of the security, the anomalies and the memorization
and cancellation of the radio codes.
SIGNAL - 24Vdc GATE OPEN WARNING LIGHT (COM A+/SIGNAL-)
Signals when the gate is open, partially open or not closed completely. It turns OFF only when
the gate is completely closed.
During opening, it flashes slowly.
When the gate is stationary or opened, it is permanently on.
During closing, it flashes quickly
N.B.: Max 3 W. If warning lights are in excess, the control panel processes will be endangered
with possible stop of all operations.
OPERATION AFTER A BLACK-OUT (WITHOUT BATTERIES)
When the power supply comes back the DL1 led turns on and remains on for all the time the gate
stays open. The led will turn OFF only once the gate is completely closed.
It is recommended to fully open the gate. Let the gate close by itself or with automatic closing,
or wait until the blinker stops flashing before commanding it to close.
This will allow the gate to realign. If, motors were released and moved from the normal position
when closed during the blackout, the first movement after power returns must be complete.
If the black out occurs when the gate is still moving or when the gate is open and the first
command sent after the black out is a closing command, the closing of the gate will be carried
out with a total delay between the two gate leaves. Therefore, first the leaf M2 will close
completely; once it is OFF, M1 will start closing. This separate movement of the two gate leaves
is done to avoid their incorrect overlapping.
TECHNICAL SPECIFICATIONS
- Temperature range
- Humidity
- Voltage
- Frequency
- Battery power
- Transformer Power
- Maximum absorption
- Power supply microinterruptions
- Maximum power SIGNAL output
- Maximum blinker power
- Power for photocells and accessories 1 A ± 15 %
- Power for radio connector
RADIO SPECIFICATIONS (model B2 24V-CRX)
- Reception frequency
- Impedence
- Sensitivity
0 ÷ 55 °C
< 95 % without condensation
230 V~ ± 10% (120 V 60 Hz upon request)
50/60 Hz
20-24 Vdc
250 VA - primary 230 Vac - secondary 18 Vac
25 mA
100ms
24 Vdc 3 W (equivalent to one 3W or 5 LED light bulb
with resistor in series at 2.2 K ohm)
24 Vdc 20 W
200 mA
433,92 MHz
52 ohm
>1 µV
- Feedback control
- Memory storage (codes)
- All inputs must be used as clean contacts because the power is generated internally (secure
power) to the board and is set up to ensure compliance with double or reinforced insulation
with regard to dangerous voltage.
- Any external circuits connected to the outputs of the control panel must be made in such
a manner as to ensure compliance with double or reinforced insulation with regard to
dangerous voltage.
- All inputs are controlled by a programmed integrated circuit that performs a self check every
time it starts operating.
TROUBLE SHOOTING
After having carried out all connections, by carefully following the layout and having positioned
the gate in intermediate position, check the correct ignition of red LEDS DL6, DL7, DL8, DL9
and DL10.
In case of no ignition of the LEDS, always with gate in intermediate position, check the following
and replace any faulty components.
DL6
OFF
Stop button malfunction (if Stop is not connected, perform the jump
between COM A+ and STOP).
DL7 or DL8
OFF
Faulty photocells (In case the edge is not connected, carry out jumper
between COM A+ and PHOTO 1/PHOTO 2)
DL9 or DL10
OFF
Faulty safety edge (In case the edge is not connected, carry out jumper
between COM A+ and EDGE 1/EDGE 2)
During functioning with personnel present, with DIP 1 at ON, check that during opening of M1
and M2 the green DL2 and DL4 LEDS switch on and that during closing of M1 and M2 the red DL3
and DL5 LEDS switch on.
Or else, reverse the wires of the motor.
DL13 blue
ON
Some functions are enabled via smartphone, so via smartphone check
the card functions as the dips/trimmers status may not be true.
On the board there are resettable fuses which intervene in the event of a short circuit,
interrupting the output assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable connectors and
insert them one at a time in order to more easily identify the cause of the fault.