ADJUSTMENTS
CHECKING THE TABLE EXTENSION
See Figure 76.
Lock the sliding table extension. The sliding table extension
should not move while locked. If the extension moves:
Lift the table extension lock lever.
Find the hex coupling located underneath the saw table.
Loosen the hex locking nuts.
Turn the hex coupling counterclockwise.
Lock the table extension lock. Push and pull on the sliding
table extension.
Readjust hex coupling if necessary.
Tighten the hex locking nuts against coupling.
HEX LOCKING
NUTS
MAINTENANCE
WARNING:
When servicing, use only identical replacement
parts. Use of any other parts could create a
hazard or cause product damage.
HEX
COUPLING
Fig. 76
50 − English
TO ADJUST THE HEIGHT OF THE TABLE EXTENSION
See Figure 77.
Lock table extension lever.
Loosen the four nuts underneath the sliding table
extension.
Use a square to make sure the top of the sliding table
extension is the same height as the main table.
Tighten the four hex nuts. Recheck and readjust if
necessary.
SQUARE
WARNING:
Always wear eye protection with side shields
marked to comply with ANSI Z87.1 during
product operation. If operation is dusty, also wear
a dust mask.
HEX NUT
TABLE
EXTENSION
Fig. 77