Ex 355
Montage- und Anschlussanleitung / Ex-Positionsschalter
Mounting and wiring instructions / Ex position switch
Instructions de montage et de câblage / Interrupteur de position Ex
Istruzioni di montaggio e collegamento / Interruttore di posizione Ex
Instruções de montagem e instalação / Chave fim de curso Ex
English
Intended use
=
DANGER
Misuse and explosive environment. Explosion haz-
ard! Risk of burns! Not for use in zone 0 and zone
20. Use only in permitted zones. Use device only in
accordance with the operating conditions defined
in the mounting and wiring instructions. Use device
only in accordance with the intended purpose de-
fined in the mounting and wiring instructions.
The device complies with the European standards for explosion protec-
tion EN IEC 60079-0, EN 60079-1, EN IEC 60079-7 and EN 60079-31.
It is intended for use in hazardous areas of zones 1 and 2 as well as
zones 21 and 22 according to EN 60079-14. Comply with the require-
ments of EN 60079-14, e.g. with regard to dust deposits and tempera-
ture limits. The device is used in safety circuits to monitor the position
of mobile safety guards to EN ISO 14119 (EN 1088) type 1 and
EN 60947-5-1.
Installation, mounting, dismantling
=
DANGER
Live parts and explosive atmosphere. Electric
shock hazard! Explosion hazard! Risk of burns!
Connecting and disconnecting only to be performed
by qualified and authorised personnel. Connecting
and disconnecting only in non-explosive
environment.
=
DANGER
Untight if mounted at low temperatures. Electric
shock hazard! Mount carefully at low temperatures.
=
DANGER
Untight if mounted without an actuator. Electric
shock hazard! Only operate with an actuator.
=
DANGER
Leakage caused by untight cover. Explosion haz-
ard! Risk of burns! Tighten the cover appropriately.
Oberserve tightening torque 1.5 - 2 Nm.
Mount the device on an even surface. Ensure that the device cannot be
moved from its position. Ensure this in case of failure, too.For protec-
tion against unauthorized manipulation, use e.g. one way safety
screws. These are optionally available. The enclosure is equipped with
two terminals for a protective conductor: one inside the enclosure for
a wire cross-section of max. 1.5 mm
4 mm
2
wire. Observe the instructions in the standards EN ISO 12100,
EN ISO 14120 and EN ISO 14119.
2
and an external one for max.
Application and operation
=
DANGER
Live parts. Electric shock hazard! Protective cover
over contacts must be intact.
=
DANGER
In case of overloaded contacts too high operation
temperatures. Explosion hazard! Risk of burns!
For short-circuit protection, use fuse size
6 A (gG/gN).
- Use device only within the permitted electrical load limits (see
technical data).
- Use device only within the permitted ambient temperature range
(see product label and technical data).
Cleaning
=
DANGER
Live parts. Electric shock hazard! When cleaning:
observe degree of protection IP67.
- Use a damp cloth to clean devices in hazardous areas. This prevents
electrostatic charge.
- In case of damp cleaning: use water or mild, non-scratching,
non-chafing cleaners.
- Do not use aggressive cleaners or solvents.
Disposal
- Observe national, local and legal regulations concerning disposal.
- Recycle each material separately.
Service, maintenance, repair
=
DANGER
Live parts. Electric shock hazard! Do not repair de-
fective or damaged devices. Replace them.
=
DANGER
Explosive atmosphere. Explosion hazard! Risk of
burns! Observe maximum switching cycles.
=
DANGER
Explosive atmosphere. Explosion hazard! Risk of
burns! Do not rebuild or modify the device in
any way.
With rough conditions, we recommend routine maintenance as follows:
1. Check actuator for easy operation.
2. Remove dirt.
3. Check sealing of the cable or conduit connections.