T6 Pro Z-Wave
Programmable Thermostat
TH6320ZW2003
TH6320ZW02
Professional Install
Guide
Package Includes:
• T6 PRO Z-Wave Thermostat
• UWP™ Mounting System
• Decorative Cover Plate
• Screws and anchors
• 3 AA batteries
• Thermostat Literature
Compatibility
• Designed for battery operation (3 x AA batteries) or for 24 VAC power operation
(via a "C" or common wire).
• Compatible with most single and multi-stage conventional and heat pump
systems.
• Designed to work with any Z-Wave compliant controller or gateway; however,
a security enabled Z-Wave Plus Controller is recommended to fully utilize all
thermostat features.
• Works with millivolt systems.
• Does not work with electric baseboard heat (120-240V).
User Guide
Visit honeywellhome.com for a complete user guide.
Customer assistance
For assistance with this product, please visit
customer.resideo.com.
Or call Resideo Customer Care toll-free at
1-800-468-1502.
(with SmartStart)
Following Schedule
PM
Mode
Fan
Heat
Auto
Wake
Away Home
Sleep
Mode
Menu
Actual size 4.09'' x 4.09'' x 1.06''
33-00587EFS-05
Fan

Publicité

loading

Sommaire des Matières pour Honeywell Home TH6320ZW02

  • Page 1 T6 Pro Z-Wave Programmable Thermostat TH6320ZW2003 Following Schedule TH6320ZW02 (with SmartStart) Professional Install Mode Heat Auto Guide Wake Away Home Sleep Package Includes: • T6 PRO Z-Wave Thermostat Mode Menu • UWP™ Mounting System • Decorative Cover Plate • Screws and anchors •...
  • Page 2 Read and save these instructions. Introduction The T6 Pro Z-Wave Programmable Thermostat is a Z-Wave Plus certified thermostat capable of controlling up to three heat and two cool stages of heat pump, (incl. dual fuel heat pump systems) and up to two heat and two cool stages of conventional system (3H/2C HP, 2H/2C Conv.) It also measures, displays and reports % indoor relative humidity;...
  • Page 3 UWP Mounting System installation 1. Open package to find the UWP. See Figure 1. 2. Position the UWP on the wall. Level and mark hole positions. See Figure 2. Drill holes at marked positions, and then lightly tap supplied wall anchors into wall using a hammer.
  • Page 4 For the rectangular cover plate Mount the cover plate on the wall using any of the 6 screw holes. Insert and tighten the mounting screws supplied with the Cover Plate. Do not overtighten. See Figure 1. Make sure the Cover Plate is level. Attach the UWP by hanging it on the top hook of the Cover Plate and then snapping the bottom of the UWP in place.
  • Page 5 Wiring UWP Push down on the tabs to put the wires into the inner holes of their corresponding terminals on the UWP (one wire per terminal) until they are firmly in place. Gently tug on the wires to verify they are secure. If you need to release the wires again, push down the terminal tabs on the sides of the UWP.
  • Page 6 Wiring UWP a single wire—the unused wire then becomes your common wire. See THP9045 instructions for more information.
  • Page 7 Wiring conventional systems: forced air and hydronics 1H/1C System (1 transformer) 1H/1C System (2 transformers) Power [1] Power (heating transformer) [1] Rc Power (cooling transformer) [1] Y [R+Rc joined by Slider Tab] [2] Compressor contactor Compressor contactor 24 VAC common [3, 4] 24 VAC common [3] Heat relay Heat relay...
  • Page 8 Wiring heat pump systems 3H/2C Heat Pump System [10] 1H/1C Heat Pump System Power [1] Power [1] [R+Rc joined by Slider Tab] [2] [R+Rc joined by Slider Tab] [2] Compressor contactor (stage 1) Compressor contactor 24 VAC common [3] 24 VAC common [3] O/B Changeover valve [7] O/B Changeover valve [7] Fan relay...
  • Page 9 Wiring heat pump systems In Installer Setup Options (ISU), set Reversing Valve to O/B on Cool (for cool changeover) or to O/B on Heat (for heat changeover). In Installer Setup Options (ISU), set heat sys- tem type to Heat Pump. Set compressor stages to 1, and set Aux/E stages to 1.
  • Page 10 Mounting thermostat Push excess wire back into the wall opening. Close the UWP door. It should remain closed without bulging. Align the UWP with the thermostat, and push gently until the thermostat snaps in place. If needed, gently pull to remove the thermostat from the UWP.
  • Page 11 • For other specific tasks such as adding the thermostat to home automation scenes or groups, refer to the user manual of your Z-Wave controller. * If the TH6320ZW02 is included in a Z Wave network that does not have SmartStart, then after initial setup, go MENU, then Z-WAVE SETUP, then START...
  • Page 12 • Thermostat is included and connected to a Z-Wave network. • Flashing Icon. (TH6320ZW02 model only.) Thermostat is in the INCLUDE MODE using SmartStart. This occurs after initial setup and time and date are set. Include mode shown on page 9.
  • Page 13 System operation setting Press the Mode button to cycle to the next available System mode. Cycle through the modes until the required System mode is displayed and leave it to activate. System modes: • Heat: Controls the heating system. • Cool: Controls the cooling system. •...
  • Page 14 Scheduling options This thermostat may be configured to be programmable or non programmable. Thermostat schedule is an optional menu item. It will only show up in the thermostat menu if enabled in the Installer setup – advanced menu. It provides setting for local thermostat schedule control.
  • Page 15 See table below with default 5+2 schedule (Mon-Fri; Sat-Sun), adjustable settings: Thermostat schedule is turned ON, thermostat included in Z-Wave network Period Start Time Heat (Mon-Fri) Cool (Mon-Fri) Heat (Sat-Sun) Cool (Sat-Sun) ° ° ° ° Away N/A* ° ° °...
  • Page 16 The screen will wake up by pressing the center area of the displayed temperature. If powered by 24 VAC, the screen stays lit for 45 seconds after you complete changes. If powered by battery only, the screen stays lit for 8 seconds. Brightness of an inactive backlight can be adjusted in the thermostat MENU only if the thermostat is powered by 24 VAC.
  • Page 17 Note: ISU options available may vary upon the thermostat model and equipment setup. # ISU ISU Name ISU Options (defaults in bold) Notes Schedule Type No Schedule or Occupancy (when included in Z-Wave network) You can change default MO-FR, SA-SU schedule here. To edit periods during days, temperature setpoints, or to turn Schedule On/Off, go to MENU/SCHEDULE (only available if schedule is set).
  • Page 18 # ISU ISU Name ISU Options (defaults in bold) Notes EM Heat Type Electric, Gas/Oil (or Fossil Forced Air) This ISU is displayed only if ISU 200 is set to Heat Pump AND if ISU 221 Aux/E heat stages = 1 AND if ISU 253 is set to run AUX/E heat separately.
  • Page 19 # ISU ISU Name ISU Options (defaults in bold) Notes Cool 1 CPH (Cooling 1 - 6 CPH (3 CPH) This ISU is only displayed when Cool /Compressor Stages is set to 1 or more stages. Cycle rate limits the maxi- mum cycle rate stage 1) number of times the system can cycle in a 1 hour period measured at a 50% load.
  • Page 20 # ISU ISU Name ISU Options (defaults in bold) Notes Adaptive Recovery On, Off Adaptive Intelligent Recovery (AIR) is a comfort setting. Heating or cooling equipment will turn on earlier, ensuring the indoor temperature will match the setpoint at the scheduled time. Minimum Cool 50 °F to 99 °F (50 °F);...
  • Page 21 # ISU ISU Name ISU Options (defaults in bold) Notes 0 - 2 Some systems may have two UV devices, one for the A-Coil and another for Air Treatment. A replacement 1100 UV Devices reminder can be setup for each one separately. 1105 UV Bulb 1 Reminder Off, 6, 12, 24 months...
  • Page 22 • Heating and cooling • Fan Identify thermostat: (TH6320ZW02 only). If the thermostat is included in a Z-Wave Network. You can choose to identify the thermostat via Z-Wave app. Backlight will flash. Touching display while flashing will stop Identify mode. This is helpful when multiple...
  • Page 23 Alerts and reminders Alerts and reminders are displayed via the alert symbol and alert number in the clock area on the home screen. You can read more information about active alerts, snooze or dismiss non-critical alerts in Menu/Alerts. Number Alert/Reminder Definition Thermostat The sensor of the thermostat has encountered Humidity...
  • Page 24 Alerts and reminders Number Alert/Reminder Definition AC Power Lost If batteries used as backup power it would drain batteries quickly so Z-Wave communication needs to be turned off. The working power mode can only be changed when thermostat is NOT included in a Z-Wave network.
  • Page 25 Z-Wave Gateway 40-90 °F (4.5-32.0 °C) identification function. Adjustable Cool Temperature Range Setting: Basic V1 (TH6320ZW2003) V2 (TH6320ZW02) 50-99 °F (10.0-37.0 °C) (basic set command implementation): Operating Ambient Temperature Range • Value 0x00 Device goes to Energy saving setting Thermostat: 37-102°F (2.78-38.89 °C)
  • Page 26 33-00587EFS—05 M.S. Rev. 10-21 | Printed in United States © 2020 Resideo Technologies, Inc. All rights reserved. The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.
  • Page 27 Z-Wave Pro T6 Thermostat programmable TH6320ZW2003 Following Schedule TH6320ZW02 (avec SmartStart) Guide d’installation Mode Heat Auto professionnelle Wake Away Home Sleep L’emballage comprend : • Thermostat Z-Wave Pro T6 Mode Menu • Système de montage UWP™ • Couvercle décoratif • Vis et ancrages Dimensions réelles 10,38 cm x 10,38 cm x 2,69 cm...
  • Page 28 Veuillez lire le mode d’emploi et le conserver en lieu sûr Introduction Le thermostat programmable Z-Wave Pro T6 est un thermostat certifié Z-Wave Plus qui peut contrôler jusqu’à trois phases de chauffage et deux phases de climatisa- tion d’une thermopompe (y compris les thermopompes bi-énergie) et jusqu’à deux phases de chauffage et de climatisation d’un système classique (3H/2C thermo- pompe, 2H/2C classique).
  • Page 29 Installation du système de montage UWP 1. Ouvrez l’emballage, puis repérez l’UWP. Voir la figure 1. 2. Placez l’UWP contre le mur. Placez-le de niveau, puis marquez l’emplacement des trous. Voir la figure 2. Percez les trous aux emplacements marqués, puis à l’aide d’un marteau, posez doucement les ancrages de mur fournis.
  • Page 30 Pour la plaque de recouvrement rectangulaire Posez la plaque de recouvrement au mur à l’aide des 6 trous de vis. Insérez et serrez les vis fournies avec le couvercle de recouvrement. Ne serrez pas excessivement. Voir la figure 1. Assurez-vous que la plaque de recouvrement est de niveau. Fixez l’UWP en l’accrochant au crochet supérieur de la plaque de recouvrement, puis en l’enclenchant en place par le bas.
  • Page 31 Réglage des languettes à glissière Système de montage UWP Réglez la languette à glissière R. • Utilisez le cavalier intégré (languette à glissière R) pour faire la différence entre les systèmes à un ou deux transformateurs. • S’il n’y a qu’un fil R et qu’il est raccordé aux bornes R, Rc ou RH, placez la glissière en position haute (un fil).
  • Page 32 Câblage des systèmes classiques: air pulsé et hydronique Système 1H/1C (un transformateur) Système 1H/1C (deux transformateurs) Alimentation [1] Alimentation (transformateur de chauffage) [1] Rc [R+Rc reliées par la languette à glissière] [2] Alimentation (transformateur de climatisation) [1] Contacteur du compresseur Contacteur du compresseur Neutre 24 V c.a.
  • Page 33 Câblage des systèmes à thermopompe Système à thermopompe 3H/2C [10] Système à thermopompe 1H/1C Alimentation [1] Alimentation [1] [R+Rc reliées par la languette à [R+Rc reliées par la languette à glissière] [2] glissière] [2] Contacteur du compresseur (phase Contacteur du compresseur Neutre 24 V c.a.
  • Page 34 Pose du thermostat Poussez l’excédent de fil dans l’ouverture du mur. Fermez la porte du UWP. Elle devrait demeurer fermée sans bomber. Alignez l’UWP avec le thermostat, puis appuyez doucement jusqu’à ce qu’il s’enclenche en position. Au besoin, tirez doucement pour retirer le thermostat de l’UWP.
  • Page 35 • Pour en savoir plus sur d’autres tâches précises, comme l’ajout du thermostat à des scènes ou groupes d’automatisation, reportez-vous au manuel de l’utilisateur de votre contrôleur Z-Wave. * Si vous utilisez le TH6320ZW02 avec un réseau Z-Wave qui n’a pas SmartStart, sélectionnez MENU, puis Z-WAVE SETUP, puis START INCLUDING.
  • Page 36 • Le thermostat est inclus et connecté à un réseau Z-Wave. • Icône clignotante. (Modèle TH6320ZW02 uniquement.) Le thermostat est en mode INCLURE avec SmartStart. Cela se produit après la configuration initiale et le réglage de l’heure et de la date.
  • Page 37 Réglage du système d’exploitation Appuyez sur le bouton Mode pour passer au prochain mode du système accessible. Parcourez les modes jusqu’à ce que vous tombiez sur le mode du système voulu, puis laissez-le pour l’activer. Modes du système : • Heat (chauffage) : contrôle le système de chauffage. •...
  • Page 38 Ce thermostat peut être configuré comme étant programmable ou non programmable. La programmation du thermostat est un élément facultatif du menu. Elle s’affiche uniquement dans le menu du thermostat si elle est activée dans la Configuration de l’installateur – menu avancé. Elle permet la programmation locale du thermostat.
  • Page 40 L’écran s’allume en appuyant au centre de la température affichée. Un écran alimenté à 24 V c.a. demeure allumé pendant 45 secondes après la programmation des modifications. Un écran alimenté par pile seulement demeure allumé pendant 8 secondes. Il est possible de régler la luminosité d’un rétroéclairage d’écran inactif au MENU du thermostat uniquement si celui-ci est alimenté...
  • Page 41 Remarque : Les options ISU disponibles peuvent varier selon le modèle du thermostat et le matériel utilisé. Nº ISU Nom ISU Options ISU (valeurs par défaut en gras) Remarques Type de programme Aucun programme ni aucune présence (lorsqu’inclus dans le Vous pouvez changer ici la programmation Lun-Ven, Sam-Dim par défaut.
  • Page 42 Nº ISU Nom ISU Options ISU (valeurs par défaut en gras) Remarques Si vous voulez configurer et contrôler séparément le chauffage auxiliaire et le chauffage d’urgence, sélectionnez Aux/E Control Both Aux/E (Aux et Urg.) , Either Aux/E (Aux ou Urg.) l’option «...
  • Page 43 Nº ISU Nom ISU Options ISU (valeurs par défaut en gras) Remarques Une température extérieure est requise pour le verrouillage du compresseur. Réglez le verrouillage du com- Balance Point Off (arrêt), -15,0 °C à 18,5 °C (en incréments de 2,5 °C ou 3,0 presseur à...
  • Page 44 Nº ISU Nom ISU Options ISU (valeurs par défaut en gras) Remarques Cette ISU ne s’affiche que lorsque le chauffage d’urgence est configuré et que l’ISU 253 : Aux/E Terminal EM Heat CPH (taux 1 - 12 CPH Control (contrôle terminal Aux/urg.) est réglée de manière à permettre un contrôle indépendant de la chaleur du cycle de chauffage auxiliaire et la chaleur d’urgence.
  • Page 45 Nº ISU Nom ISU Options ISU (valeurs par défaut en gras) Remarques Temperature Control Cette ISU ne s’affiche que lorsque le capteur intérieur est configuré – ISU 500. Vous pouvez choisir la source Thermostat, Wired (câblé), Average (moyenne) (contrôle de la tempé- de température à...
  • Page 46 • Ventilateur Identifiez le thermostat : (TH6320ZW02 uniquement). Si le thermostat est inclus dans un réseau Z-Wave, vous pouvez choisir d’identifier le thermostat via l’application Z-Wave. Le rétroéclairage se met à clignoter. Si vous touchez l’écran pendant qu’il clignote, le mode d’identification s’arrête.
  • Page 47 Alertes et rappels Les alertes et rappels s’affichent au moyen du symbole et du code d’alerte dans la zone de l’horloge sur l’écran d’accueil. Vous pouvez en savoir plus sur les alertes actives, mettre les alertes en veille ou supprimer les alertes non critiques depuis le menu Alertes. Code Alerte/Rappel Définition...
  • Page 48 Alertes et rappels Code Alerte/Rappel Définition Perte de l’alimen- Si des piles sont utilisées comme alimentation auxiliaire, tation secteur leur autonomie serait grandement réduite. Ainsi, la communication Z-Wave doit être désactivée. Le mode d’alimentation principal peut seulement être changé lorsque le thermostat n’est PAS intégré à un réseau Z-Wave.
  • Page 49 V2) Jusqu’à 2 phases de chauffage/2 de climatisation Basic V1 (De base V1) (TH6320ZW2003) – classique Basic V2 (De base V2) (TH6320ZW02) Battery V1 (Pile V1) Alimentation : Clock V1 (Horloge V1) Alimentation par piles : trois piles alcalines AA Configuration V4 Câble C : 18-30 V c.a.;...
  • Page 50 1985 Douglas Drive North, Golden Valley, MN 55422 1-800-468-1502 www.resideo.com 33-00587EFS—05 M.S. Rev. 10-21 | Imprimé aux États-Unis a marque de commerce Honeywell Home est utilisée avec © 2020 Resideo Technologies, Inc. l’autorisation d’Honeywell International, Inc. Ce produit est Tous droits réservés.

Ce manuel est également adapté pour:

T6 pro z-waveTh6320zw2003