Specifications
Model Numbers:
TH6320ZW2003, TH6320ZW02
Model Name: T6 Pro Z-Wave Thermostat
Model Description: Programmable Z-Wave
thermostat with touchscreen
Stages:
Up to 3 Heat / 2 Cool Heat Pump
Up to 2 Heat / 2 Cool Conventional
Power Requirements
Battery power: AA alkaline battery 3pcs.
C-wire input: 18-30VAC; 50Hz-60Hz
Electrical Ratings:
Terminal
W Heating
(Powerpile)
W2 (Aux) Heating
E Emergency Heat
Y Compressor
Stage 1
Y2 Compressor
Stage 2
G Fan
O/B Changeover
L/A Input
Dimension: 4.09" x 4.09" x 1.06"
Display Size: 6.55 sq. in.
Temperature Ranges
Adjustable Heat Temperature Range Setting:
40-90 °F (4.5-32.0 °C)
Adjustable Cool Temperature Range Setting:
50-99 °F (10.0-37.0 °C)
Operating Ambient Temperature Range
Thermostat: 37-102°F (2.78-38.89 °C)
Operating Relative Humidity Range
Thermostat: 5% to 90% (non-condensing)
Temperature Sensor Accuracy
Thermostat: ± 1.5 °F at 70 °F (0.85 °C at 21.0 °C)
Physical Dimensions in Inches (mm) (H x W x D)
T6 PRO Z-Wave Thermostat
(TH6320ZW2003, TH6320ZW02):
4-5/64 x 4-5/64 x 1-1/16 (104 x 104 x 27)
UWP Mounting System (included):
2-9/32 x 2-13/64 x 2-43/64 (58 x 56 x 10)
Z-Wave Radio:
Frequency (USA and Canada): 908.42 MHz
Certified: Z-Wave Plus V1 (TH6320ZW2003) V2
(TH6320ZW02)
Generic Device Type: Thermostat
Node type (C-wire): Always On Slave (AOS)
Node type (Battery): Listening Sleeping Slave (LSS)
Z-Wave Chipset: ZM5202AU (TH6320ZW2003)
ZGM130S (TH6320ZW02)
Voltage
Running
(50/60Hz)
Current
18-30 Vac
0.02-1.0 A
750 mV DC
100 mA DC
18-30 Vac
0.02-1.0 A
18-30 Vac
0.02-0.5 A
18-30 Vac
0.02-1.0 A
18-30 Vac
0.02-1.0 A
18-30 Vac
0.02-0.5 A
18-30 Vac
0.02-0.5 A
18-30 Vac
0.02-0.5 A
Supported Z-Wave Command Classes:
Indicator V3
Multi Channel Association V3
Firmware Update Meta Data V5
Z-Wave Plus Info V2
Supervision V1
Transport Service V2
Association V2
Version V2
Association Group Information V2
Basic V1 (TH6320ZW2003)
Basic V2 (TH6320ZW02)
Battery V1
Clock V1
Configuration V4
Device Reset Local V1
Manufacturer Specific V2
Sensor Multilevel V5
Notification V3
Powerlevel V1
Security 2 V1
Thermostat Fan Mode V3
Thermostat Fan State V1
Thermostat Mode V3
Thermostat Operating State V1
Thermostat Setpoint V2
NOTES:
Thermostat Mode V3:
• Some of the reported modes are manufacturer
specific if not covered by the Z-Wave command
class.
Indicator V3: (TH6320ZW02)
• The thermostat supports the LCD Backlight as
the Indicator (ID 0x30).
• The thermostat supports indicator (ID 0x50). To
trigger this feature, use your Z-Wave Gateway
identification function.
Basic V1 (TH6320ZW2003) V2 (TH6320ZW02)
(basic set command implementation):
• Value 0x00 Device goes to Energy saving setting
(AWAY mode)
• Values 0x01-0x63 and 0xFF Device goes to
Comfort setting (HOME mode)
Notification V3:
• Notification V3 is enabled by default (Power
management alarm handling). Notification
Type: Power Management (0x08). Notification
Events: AC mains disconnected (0x02), AC mains
re-connected (0x03).
Security:
• All supported Z-Wave Command classes are
supported securely, except Transport Service V2,
Security 2 V1 and Z-Wave Plus Info V2
Association V2:
• Group ID: 1; Maximum Nodes: 1; Description:
Z-Wave Plus Lifeline.
• Group 1 notifies an associated device of a change
occurring in the thermostat. The changes include
status of the sensors, operating modes, state of
the thermostat, etc.
• Command Classes reported: Multilevel Sensor,
Thermostat Setpoint, Thermostat Mode,
Thermostat Fan Mode, Thermostat Operating
State, Thermostat Fan State, Basic, Battery,
Device Reset, and Notification.
23