Thermostat controls
Fan Switch is used to
control your fan.
In "Auto" mode, the
fan runs only when the
heating or cooling system
is on.
If set to "On," the fan runs
continuously
Battery replacement
Install fresh batteries when the REPLACE BATT warning begins
flashing, once a year, or before leaving home for more than
a month. The warning flashes about two months before the
batteries are depleted.
Batteries provide backup power to the display during power
interruptions if your thermostat was wired to run on AC power
when installed. All settings are permanently stored in memory,
and do not require battery power.
Pull at bottom
to remove
thermostat
from wallplate.
Digital display
Temperature buttons
Press the up or down
buttons until you reach the
desired temperature.
System switch is used to control
your heating or cooling system.
Cool: Cooling system control.
Off: All systems off.
Heat: Heating system control.
Em Heat: Emergency & Auxiliary
Heat control. Compressor is
locked out. (Select models only.)
Turn thermostat
over, insert fresh AA
alkaline batteries,
then reinstall
thermostat.
PRO
3000
TH3110D1008
TH3210D1004
Display screen
Temperature
Current inside
setting (or Desired
temperature
Temperature
when changing
temperature)
Low battery
Inside
warning
75
Replace Batt
If "Heat On" or "Cool On" is
flashing, compressor protection
is engaged.
Built-in compressor protection
This feature helps prevent
damage to the compressor in
your air conditioning or heat
pump system.
Damage can occur if the
compressor is restarted too
soon after shutdown. This
feature forces the compressor
to wait 5 minutes before
restarting.
During the wait time, the
display will flash the message
Cool On (or Heat On if you
have a heat pump). When the
safe wait time has elapsed,
the message stops flashing
and the compressor turns on.
Product Manuals
Search online for Resideo 69-1929EFS for the Installation Guide.
Search online for Resideo 69-1776EFS for the User Guide.
Input: 24 V~ @ 60 Hz, 1.0 A
Electrical Ratings
System
Voltage (50/60 Hz)
Heat (1st stage)
20-30 Vac
(Powerpile)
750 mV DC
Emergency heat
20-30 Vac
Auxiliary heat
20-30 Vac
Cooling
20-30 Vac
Series
System Status
Cool On: Cooling
system is on.
Heat On: Heating
system is on.
Set To
75
Em: Emergency
heat is on. **
Aux: Auxiliary
Em Aux
heat is on. **
Heat On
**Only for heat
pumps with this
capability (select
models only).
Inside
Set To
75
75
Cool On
Message flashes until safe
restart time has elapsed.
Running Current
0.02-1.0 A
100 mA DC
0.02-1.0 A
0.02-1.0 A
0.02-1.0 A