Note: ISU options available may vary upon the thermostat model and equipment setup.
# ISU
ISU Name
ISU Options (defaults in bold)
120
Schedule Type
No Schedule or Occupancy (when included in Z-Wave network)
MO-SU = Every day the same
MO-FR, SA, SU = 5-1-1 schedule
MO-FR, SA-SU = 5-2 schedule
Each Day = Every day individual
Fahrenheit, Celsius
125
Temp Scale
130
Outdoor Temp
No, Wired
Conventional Forced Air
200
System Type
Heat Pump
Boiler
Cool Only
205
Equipment Type
Conventional Forced Air Heat:
Standard Efficiency Gas (STD GAS), High Efficiency Gas (EFF
GAS), Oil, Electric, Hot Water Fan Coil
Heat Pump:
Air To Air, Geothermal
Boiler:
Hot Water Radiant Heat, Steam
218
Reversing Valve
0/B on Cool, 0/B on Heat
220
Cool Stages
0, 1, 2
(#200=Conv./
200=HP)
221
Heat Stages;
Heat Stages: 0, 1, 2
Aux/E Stages
AUX/E Stages: 0, 1
(#200=Conv.;
200=HP)
230
Fan Control
Equipment, Thermostat
Both Aux/E, Either Aux/E
253
Aux/E Control
255
Aux Heat Type
Electric, Gas/Oil (or Fossil Forced Air)
Notes
You can change default MO-FR, SA-SU schedule here. To edit periods during days, temperature setpoints, or to
turn Schedule On/Off, go to MENU/SCHEDULE (only available if schedule is set).
An outdoor temperature is required to set the following ISUs: ISU 355 Balance point (Compressor Lockout),
ISU 356 Aux Heat Lockout. Use a wired outdoor sensor connected to the "S" terminals on the UWP and set this
ISU to Wired. ("Wiring heat pump systems" on page 7.)
Basic selection of system your thermostat will control.
This option selects the equipment type your thermostat will control. Note: This option is NOT displayed if
ISU 200 is set to Cool Only.
This ISU is only displayed if ISU 200 is set to Heat Pump. Select whether reversing valve O/B should energize
on cool or on heat.
Maximum of 2 Heat Stages for conventional systems. Maximum of 1 Aux/E stages for heat pump systems.
This ISU is only displayed if ISU 205 is set to Electric Forced Air or Fan Coil.
Set "EITHER AUX/E" if you want to setup and control of Auxiliary and Emergency heating separately . This ISU
is only displayed if ISU 200 is set to Heat Pump AND if ISU 221 Aux/E stages = 1.
This ISU is displayed only if ISU 200 is set to heat pump AND if ISU 221 Aux/E heat stages = 1.