24. Correction of Malfunctions
Problem
Problem
No coating material
emerges from the
nozzle
Coating material
drips from the
nozzle
Atomisation too
coarse
Spray jet pulsates
Coating material
causes "paint tears"
Too much fog of
coating material
(Overspray)
Paint in the
ventilating hose
34
Cause
Cause
Device not switched on
Nozzle clogged
Feed tube clogged
Material quantity too small
Feed tube loose
No pressure build-up in container
Ventilating bore (Fig. 14, 1)
clogged
Nozzle loose
Nozzle worn
Nozzle seal is missing or worn
Coating material assembly at air
cap, nozzle or needle
Coating material too thick
Material volume too large
Nozzle clogged
Air cap assembled incorrectly
Air filter heavily soiled
Too little pressure build-up in
container
Amount of air too low
Coating material in container
running out
Air filter heavily soiled
Nozzle seal is missing or worn
Too much coating material
applied.
Distance to the object too large
Too much coating material
applied
Amount of air too high
Diaphragm soiled
Diaphragm defective
W 590 Flexio
Remedy
Remedy
Press the ON/OFF switch
on the side of the device
Clean
Clean
Increase the quantity of
material
Insert
Tighten container
Clean
Tighten
Change
Change
Clean
Dilute
Reduce the material
volume
Clean
Snap air cap properly
into place (fig. 19, 2)
Change
Tighten container
Increase air quantity
Refill
Change
Change
Reduce the material
volume
Reduce distance
Reduce the material
volume
Decrease air quantity
Clean the diaphragm
Replace the diaphragm