Télécharger Imprimer la page

GENERGY CUBE 2 Serie Instructions D'utilisation page 93

Publicité

Les langues disponibles

Les langues disponibles

Noise level measurements:
 The noise level at 7 m is the average sound level (LpA) obtained in four
directions and 7 meters from the generator.
NOTE: The level noise may change noticeably in different environments.
Used harmonized standards
ISO8528-13:2016: Reciprocating internal combustion engine driven generating sets
Applicable EC Directives
2006/42/EC:
EU/2016/1628:
2014/30/EU:
2014/35/EU:
2000/14/EC (amended 2005/88/EC):
2011/65/EU:
(EC)NO-1907/2006
Environmental correction
Power specifications indicated are with the following values:
Altitude:0m
Ambient temperature:25º
Factor "A" of environmental correction (Temperature and altitude):
Altitude
(meters)
25
0
1
500
0,93
1000
0,87
2000
0,75
3000
0,64
4000
0,54
Factor "B" of environmental correction (humidity):
 Relative humidity 60 %
 Relative humidity 80%
 Relative humidity 90%
 Relative humidity 100%
Example of power calculation according to atmospheric conditions.
3KW generator,
altitude: 1000m, Temperature: 35℃, Humidity: 80%
Power rating x (Factor A – factor B) = Real Power
3
x (0.82
Machinery directive
Emissions machines powered by engine
Electromagnetic compatibility
Low voltage directive
Noise emission directive
RoHS directive
REACH regulation
Ambient temperature (degrees Celsius)
30
35
0,98
0,96
0,91
0,89
0,85
0,82
0,73
0,71
0,62
0,6
0,52
0,5
correction factor C - 0.01
correction factor C - 0,02
correction factor C - 0,03
correction factor C - 0,04
-
0.02)
=
92
Relative humidity:30%
40
0,93
0,87
0,80
0,69
0,58
0,48
2.4KW
45
0,90
0,84
0,78
0,66
0,56
0,46

Publicité

loading