Failure
(2) The pump does not
"pulse" during the day.
(3) Yellow LED is lit, but the
pumps connected do not
operate.
(4) The
Multicontroller
operates with a very low
output only.
(5) The automatic interval
system does not work.
Cause
(a) The photo-electric cell
gets too little light, is
covered with algae or has
been attached wrongly.
(a) The pump is defective.
(b) The connecting cable is
defective.
(c) The Multicontroller is
defective.
(a) The output on the driver
has not been set to 100
per cent.
(a) No pump has been
connected up to socket
(9) or (11).
Remedy
(a) Clean the photo-electric
cell; re-attach the cell if
and when necessary.
Check the parts, and repair or
replace them, if and when
necessary.
(a) Turn
the
adjusting screw on the
driver clockwise to stop,
i.e. to 100 per cent.
(a) At least one pump has to
be connected to socket
(8) or (10).
"Power"
37