10. SECURING THE BOTTLE OPENER
Parts Required:
1
x
Bottle Opener (#12)
Installation:
•
Secure the bottle opener onto the right-front leg using the pre-
installed screws on the leg.
11. PLACING THE GREASE BUCKET
Parts Required:
1
x
Grease Bucket (#13)
Installation:
•
Place the grease bucket on the spout hook on the end of the main
barrel. Ensure it is level to avoid grease spills.
•
The unit is now completely assembled.
12. CONNECTING TO A POWER SOURCE
NOTE: Before plugging your Pit Boss® into any electrical outlet,
ensure the temperature dial is in the OFF position.
•
STANDARD OUTLET
This appliance requires 110-120 volt, 60hz, 275W, 5 amp service. It
must be a 3-prong grounded plug. Ensure grounded end is not broken
off before use. The control uses a 5 amp, 120 volt, fast-blow fuse to
protect the board from the igniter.
•
GFCI OUTLETS
This appliance will work on most GFCI outlets, with a recommended
size of 15 amp service. If your GFCI outlet is highly sensitive to power
surges, it will likely trip during the start-up phase of operation. During
the start-up phase, the igniter draws 200-700 watts of electricity
which can be too much power for a GFCI outlet to handle. Each time it
trips, it increases in sensitivity. If the GFCI keeps tripping, replace the
outlet or change to a non-GFCI outlet.
ON THE ROAD
•
Disconnect the igniter from the main wiring harness. Use the manual
start-up procedure. A Pit Boss® unit can operate using a 12 volt,
100 watt inverter plugged into your automobile outlet. To use the
automatic igniter, it is recommended to use a minimum of a 1000 watt
inverter.
IMPORTANT: Disconnect unit from power source when not in use.
10
12
11
13
12
FAST-BLOW FUSE,
5 AMP
11