CAUTION! RISK OF INJURY!
Make sure that all parts are undamaged
and correctly assembled. Improper instal-
lation may result in injury. Damaged
parts could impact safety and function.
Installation must be performed by skilled
persons.
RISK OF WATER DAMAGE!
Shut off the main water supply prior to
installation.
Ensure all seals are seated correctly.
This product is not suitable for use with
low-pressure tanks and open (non-pressur-
ised) electrical storage heaters.
Only use the product in rooms with tem-
peratures above 0 °C. In case of potential
frost, shut off the water supply and drain
the product.
Careful when adjusting the water
temperature: risk of scalding!
Please note that the seals are wear parts
and must be changed from time to time.
Incorrectly installed hand shower sets can
cause water damage!
Even careful production can result in sharp
edges. Therefore proceed with caution
during installation.
Installation
Note: carefully check all connections for
leaks after first use.
Note: incorrect installation will void the
warranty, particularly with respect to conse-
quential damage!
Note: following installation, unscrew the
aerator
and flush the pipe and tap fitting
5
well (hot / cold water supply) to flush out
contaminants (shavings and hemp residues).
After flushing the tap fitting, reattach the
aerator
to the tap fitting.
5
Note: thoroughly flush the lines after ex-
tended periods of non-use to remove stag-
nant water and residues.
Roughen the (smaller) 1/2 thread of the
S-connectors
with a saw (see Fig. A).
1
Wrap the 1/2 threads of the S-connec-
tors
with sealing tape (not included)
1
(see Fig. B).
Screw the two S-connectors
into the wall connections. When doing
so, be sure the S-connectors
square with the wall and must be
screwed in equally (see Fig. C).
Adjust the S-connectors
of the S-connectors
connectors on the fitting
S-connectors
are horizontal (see Fig. D).
1
Screw one covering collar
over each (larger) thread of the installed
S-connectors
so they are flush with the
1
wall (see Fig. E).
Insert the seals
3
Secure the tap fitting
union nuts onto the threads of the two
S-connectors
. Please note that the
1
union nuts must be easy to screw on and
must not tilt to avoid leaking connections
(see Fig. F).
For the thermostat bath filling-fitting
(CLT023SICR-L)
4
anti-clockwise following installation,
5
flush the pipes and the tap fitting well
(hot / cold water supply) to flush out con-
taminants (shavings and hemp remains).
After flushing the tap fitting
the aerator
by screwing it in clockwise
5
(see Fig. G).
Note: If required, you will receive a
detailed explanation on how to replace the
thermostat element from our customer service.
Switching between bath
filling / shower functions
(only CLT023SICR-L)
With the water running from the tap fit-
ting
, turn the diverter knob backwards
4
to switch to the shower function (see Fig. H).
Turn the diverter knob forwards to stop
the shower function (see Fig. I).
clockwise
1
are
1
so the distance
1
is the same as the
1
. Ensure the
4
clockwise
2
in the union nuts.
by screwing the
4
, unscrew the aerator
, reinstall
4
GB/IE