aVec un Ventilateur en option seuleMent (sans proflaMe GtMf)
Lockwasher
Star washer
(for mobile home)
Nut
Fan
ground wire
Electrical Connection Alternative Scheme "A",
Power at Stove
Wall Junction Box
~
Wire Nuts
14 AWG wire
*Wire Clamp
*Receptacle Box
inside stove
*Receptacle
(dedicated use
by stove fan only)
Copper Ground
120 Volts
White (Neutral)
60 Hz
Black (Hot)
14 AWG wire
AVERTISSEMENT : Assurer que les fils
ne touchent pas les surfaces chaudes
et sont loin des côtés pointu.
Regency Horizon HZ30E Foyer à Gaz
scHÉMaMe du filaGe
#8 Ground Lug
120V AC
60 Hz
*Speed Control
Switch with
lead wires
(Regency)
120 Volts
60 Hz Copper Ground
Wire Nuts
* = supplied with fan kit
Other parts are to be supplied
by electrician or installer
Ground
Black
Neutral
Live
Ground
Black
NOTE: Wiring schematics for HZ54E (120 Volts),
plug-in fan circuit with speed control switch on wall.
Electrical Connection Alternative Scheme "b"
power at switch
Wall Junction Box
~
"Plug-in Fan" circuit supplied by Regency
Black (Hot)
White (Neutral)
Convection Air Temperature Switch
Wire
(Thermodisc - normally open)
Black (Hot)
Green (Ground)
Black (Neutral)
Power Cord
attention: Marquer tous les fils avant le
débranchage en entretenant des commandes.
les erreurs de câblage peuvent causer l'opération
inexacte et dangereuse.
installation
Fan
White
Black
Green
Black
Fan Thermodisc
(normally open)
HZ30E
*Speed Control
Switch with lead wires
Green
Wire Nuts
Black
White
14 AWG wire
Ground
*Wire Clamp
*Receptacle Box
inside stove
Black
Black
*Receptacle
(dedicated use
by stove fan only)
Black
Fan
35