CAUTION: To maintain the IP 68 it is important to screw the cable glands fully and screw the screws with a PZ.1
head and a tightening torque of 0.9 N.m.
As a reminder the probe 1 is on the rounded side of the housing, the probe 2 is on the flat side of the housing.

5.3. Wiring external supply

A terminal is present in the product to connect an external supply in order to:
- Improve the autonomy of the product
FR
- Send more frames more regularly.
EN
5V + -
V+
GND
1 2 3 4
Connect the power cable to the "+" terminal block (V +) with a
power supply between 4.5 V and 6.5 V and connect the earth to the
"-" (GND).
N.B .: To power the product via an external power supply it is nec-
essary to disconnect a probe in order to pass the cable of the power
supply in the cable gland.
N.B: It is not necessary to disconnect the battery when the external
power supply is connected.