Page 1
WMBUS TEMP Ready-To-Use Temperature Device Guide utilisateur / User Guide Version 2.0.0 Ce Guide utilisateur s’applique à partir des versions logicielles suivantes : This User Guide applies from the following firmware versions: Version RTU : V00.04.00 Version APP : V01.03.03 adeunis ®...
Page 2
Ninguna parte de este documento puede ser reproducida o transmitida (en fotocopias electrónico o en papel, o) sin el acuerdo adeunis®. Este documento puede ser modifi cada sin previo aviso. Todas las marcas comer- ciales mencionadas en esta guía son el tema de los derechos de propiedad intelectual.
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 TABLE DES MATIERES FRANCAIS INFORMATIONS PRODUIT ET REGLEMENTAIRES PRESENTATION DU PRODUIT 1.1. Description générale 1.2. Encombrement 1.3. Carte électronique 1.4. Spécifications Techniques 1.4.1 Caractéristiques générales 1.4.2 Autonomie 1.4.3 Caractéristiques des sondes FONCTIONNEMENT DU PRODUIT 2.1.
Page 4
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 ENGLISH PRODUCTS AND REGULATORY INFORMATION PRODUCT PRESENTATION 1.1. General description 1.2. Dimensions 1.3. Electronic board 1.4. Technical Specifications 1.4.1 General characteristics 1.4.2 Autonomy 1.4.3 Sensor characteristics PRODUCT OPERATION 2.1. Global operation 2.1.1 PARK MODE...
Ce document et l’utilisation de toute information qu’il contient, est soumis à l’acceptation des termes et conditions adeunis®. adeunis® ne donne aucune garantie sur l’exactitude ou l’exhaustivité du contenu de ce document et se réserve le droit d’apporter des modifi cations aux spécifi cations et descriptions de produit à tout moment sans préavis.
Page 7
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 Déclaration UE de Conformité Nous adeunis 283 rue LOUIS NEEL 38920 Crolles, France 04.76.92.01.62 www.adeunis.com Déclarons que la DoC est délivrée sous notre seule responsabilité et fait partie du produit suivant : Modèle produit :...
Page 9
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 RECOMMANDATIONS ENVIRONNEMENTALES Tous les matériaux d’emballage superfl us ont été supprimés. Nous avons fait notre possible afi n que l’emballage soit facilement séparable en trois types de matériaux : carton (boîte), polystyrène expansible (matériel tampon) et poly- éthylène (sachets, feuille de protection en mousse).
Page 10
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 RECOMMANDATIONS D’USAGE • Avant d’utiliser le système, vérifi ez si la tension d’alimentation fi gurant dans son manuel d’utilisation corres- pond à votre source. Dans la négative, consultez votre fournisseur.
NOTE IMPORTANTE : le démarrage du WMBUS TEMP ne peut se faire que grâce à un aimant. Description : • Le WMBUS TEMP d’adeunis® est un appareil radio prêt à l’emploi permettant de mesurer des températures et de les envoyer sur un réseau sans-fil.
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 1.2. Encombrement Valeurs en millimètres 49,50 1.3. Carte électronique 49,50 Antenne interne Module RF Batterie interne Protocole WMBUS 49,50 Port USB pour configura- tion produit 12 of 77...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 2. FONCTIONNEMENT DU PRODUIT 2.1. Modes de fonctionnement NOTE IMPORTANTE : adeunis® utilise le format de données Big-Endian Le produit dispose de plusieurs modes de fonctionnement : MODE PARC Présence d’un aimant sur le produit >6s...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 2.1.4 Mode REPLI Le produit entre dans ce mode très basse consommation suite à la détection d’un niveau de batterie trop faible. Dans ce mode, le produit se réveille toutes les 5 secondes pour faire clignoter 2 fois la LED rouge.
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 2.2.2 Transmission sur dépassement de seuil Le produit permet la détection de dépassement de seuil (haut et bas) pour chaque capteur selon le schéma suivant : Produit en veille Période sur échantillon-...
Page 17
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 Explication des seuils et hystérésis : La période de scrutation des capteurs est égale à la période d’acquisition (registre 332) divisée par le facteur de sur-échantillonnage (registre 333). Les paramètres associés à ce mode de fonctionnement sont : •...
Page 18
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 Exemple : Registre Codage de la valeur Valeur Résultat S301 Décimal Mode évènementiel S320 Hexadécimal 0xD0 Identifiant du capteur interne mis à 0xD S322 Hexadécimal 0x80 Identifiant du capteur externe mis à 0x8 S321 Hexadécimal...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 2.2.3 Transmission d’une trame de vie journalière En mode évènementiel (seuil), le produit pourrait ne jamais envoyer de trames de données. Ainsi, pour s’assurer du bon fonctionnement de celui-ci une trame de vie est transmise régulièrement selon le schéma suivant : En mode périodique (registre 301 différent de 0), il n’y a pas d’émis-...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 2.3. Fonctionnement des LEDs Mode Etat Led Rouge Etat Led Verte Emission de trame (mode TEST seulement) Allumé pendant l’émission Réception de trame (mode TEST seulement) Allumé pendant la réception d’une trame de...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 CONFIGURATION DU PRODUIT La configuration du produit se fait au moyen du connecteur USB. Cette connexion permet de communiquer avec le produit par un port com virtuel et d’envoyer des commandes AT pour modifier les paramètres du produit.
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 3.2. Mode commande Utiliser un terminal port COM pour communiquer avec le produit. Nous utilisons le soft terminal port COM HERCULES disponible en télécharge- ment gratuit à l’adresse suivante : http://www.hw-group.com/products/hercules/index_en.html...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 3.3. Commande AT Une commande débute avec les 2 caractères ASCII : « AT », suivis d’un ou plusieurs caractères et données (voir ci-après la syntaxe des com- mandes AT disponibles sur le modem).
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 3.4. Description des registres A la mise sous tension le produit fonctionne selon la dernière configuration sauvegardée (configuration usine si c’est la première mise sous tension, ou si cette configuration n’a pas été changée).
Page 25
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 Configuration du comportement événe- Hexadécimal Défaut 0x03 mentiel du capteur interne Bits 0 à 1 : Déclenchement sur seuil • 0 = Aucun • 1 = Bas uniquement • 2 = Haut uniquement •...
Page 26
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 Ces registres doivent être manipulés avec précaution car susceptibles d’engendrer des problèmes de communication ou de non-respect de la législation en vigueur. Description Codage Détails gistre Canal WMBUS Décimal Défaut : 24 Min/max : 4 à...
Page 27
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 Canal Format (A ou B) Mode résultant Fréquence associée S2, S1M 868,300 MHz 868,300 MHz T1, T2 868,950 MHz 868,300 MHz R2 /C0 868,030 MHz R2 /C1 868,090 MHz R2 /C2...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 4. DESCRIPTION DES TRAMES Le produit transmet des informations brutes en provenance des capteurs en utilisant le protocole Wireless M-BUS. Vous trouverez dans ce chapitre les informations permettant de décoder la trame Wireless M-Bus ainsi que les données utiles.
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 4.2.1.02 Status byte L’octet de statut (status byte) est décomposé de la manière suivante : Alarm Status Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1...
Page 30
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 • Octet 6=0x80 : registre 322 : l’identifiant du capteur externe donné par l’utilisateur est égal à 0x8 • Octet 7=0x02 : registre 323 : détection de seuils haut uniquement pour le capteur externe •...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 4.2.3 Trame d’information sur la configuration du réseau Lors du passage en mode exploitation (sortie du mode PARC ou COMMANDE), la trame suivante (0x20) représentant la configuration réseau du produit est transmise :...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 Dans l’exemple en gris cela donne : • Octet 2=0xD1 : o Bits 0 à 3 = 0x1 : la sonde interne est bien présente o Bits 4 à 7 = 0xD : l’identifiant du capteur interne défini par l’utilisateur est égal à 0xD •...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 Dans l’exemple en gris cela donne : • Octet 2=0xD1 : o Bits 0 à 3 = 0x1 : la sonde interne est bien présente o Bits 4 à 7 = 0xD : l’identifiant du capteur interne défini par l’utilisateur est égal à 0xD •...
6 secondes de sorte à confirmer le démarrage du produit. Lorsque l’aimant est bien détecté, la LED verte s’allume pendant 1 seconde. Une fois que le WMBUS TEMP valide son démarrage, il émet ses trames de statut puis, après le temps de la période d’émission défini, une trame de donnée.
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 5.3. Fermeture du boîtier Une fois les étapes précédentes effectuées, vous pouvez fermer le boiter du WMBUS TEMP. Procédure : Assurez-vous que le joint d’étanchéité est bien en place sur la semelle Clipsez la carte électronique sur la semelle du boîtier.
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 6. INSTALLATION ET UTILISATION 6.1. Positionnement correct des émetteurs Deux règles sont primordiales pour une optimisation des portées radio. • La première consiste à positionner votre produit le plus haut possible.
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 Pour retirer celui-ci, tirer vers le bas sur le levier jusqu’à ce que les Ergots ergots de blocage soient face à une partie dégagée et retirer le levier Partie dégagée 6.2.2 Fixation par vis...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 6.2.3 Fixation Rail-DIN Ce système, intégré au boîtier, permet de fixer le produit sur un rail standard de 35mm • Pour installer le boîtier, placer les inserts supérieurs sur le rail et abaisser le produit pour le clipser •...
APP version:V01.03.03 DISCLAIMER This document and the use of any information contained therein, is subject to the acceptance of the adeunis® terms and conditions. They can be downloaded from www.adeunis.com. adeunis® makes no warranties based on the accuracy or completeness of the contents of this document and reserves the right to make changes to specifi...
Page 41
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 EU Declaration of Conformity adeunis 283 rue LOUIS NEEL 38920 Crolles, France 04.76.92.01.62 www.adeunis.com Declare that the DoC is issued under our sole responsibility and belongs to the following product:...
Page 43
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 ENVIRONMENTAL RECOMMENDATIONS All superfl uous packaging materials have been eliminated. We have done everything possible to make it easy to separate the packaging into three types of materials: cardboard (box), expanded polystyrene (fi ller material) and polyethylene (packets, foam protective sheets).
Page 44
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 RECOMMANDATIONS REGARDING USE • Before using the system, check that the power supply voltage shown in the user manual corresponds to your supply. If it doesn’t, please consult your supplier.
• This product meets the needs of users who require to remotely monitor internal and external temperatures of storage rooms, meeting rooms, cold rooms, etc. • The use of the WMBUS TEMP protocol allows the user to integrate the WMBUS TEMP into any network that is already deployed. • The WMBUS TEMP is fitted with internal and external probes.
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 1.4. Technical Specifications 1.4.1 General characteristics Parameters Value Supply voltage Nominal 3.6V Power supply Removable battery version: SAFT LS14500 Maximal courant 90mA Working temperature -25°C / +70°C Dimensions: 105 x 50 x 27mm...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 2. PRODUCT OPERATION 2.1. Global operation Important: adeunis® use the most significant byte first format. The product has several operating modes: PARK MODE Presence of a magnet on the product >6s...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 2.1.4 REPLI mode The product enters this very low consumption mode following the detection of a level of battery that is too low. In this mode the product wakes up every 5 seconds to make the red LED flash twice.
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 2.2.2 Transmission over threshold The product allows the detection threshold overrun (upper and lower) for each sensor according to the following diagram: Product in standby Sampling period reached? Internal tempe-...
Page 51
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 Explanation of thresholds and hysteresis: high threshold High threshold - high threshold hysteresis Sensor value Low threshold + low threshold hysteresis Low threshold Low alarm enabling Low alarm disabling High alarm enabling High alarm disabling The period of monitoring by the sensors is equal to the period of acquisition (register 332) divided by the super-sampling factor (register 333).
Page 52
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 E.g.: Registre Codage de la valeur Valeur Résultat S301 Décimal Event mode S320 Hexadécimal 0xD0 Identifier of the internal sensor set to 0xD S322 Hexadécimal 0x80 Identifier of the external sensor set to 0x8 S321 Hexadécimal...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 2.2.3 Transmission of a daily Keep Alive frame In the event (threshold) mode only, it is possible that the product would never send data frames. So to be sure that it is working properly a Keep...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 2.3. Operation of the LEDs Mode LED red state LED green state Transmission of frame (TEST mode only) ON during the transmission cycle Reception of frame (TEST mode only) ON during the reception of a downlink frame...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 DEVICE CONFIGURATION The device can be configured using the USB connector. This connection allows you to communicate with the device via a virtual com port and to transmit AT commands in order to modify the parameters of the device.
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 3.2. Command mode Use a COM port terminal in order to communicate with the device. We use the HERCULES COM port soft terminal available to download for free by clicking on the following link: http://www.hw-group.com/devices/hercules/index_en.html •...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 3.3. AT commands A command starts with 2 ASCII characters: “AT”, followed by one or more characters and data (see the list below for the syntax of AT com- mands available on the modem).
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 3.4. Description of the registers On switching on the product works according to the last saved configuration (Factory Configuration if it is the first start, or if this configuration has not been changed). Commands such as Modification TTY<n>=<M> or ATR allow you to change the content of the registers: <n> repre- senting the number of the register and <m>...
Page 59
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 Configuring the event behaviour of the Hexadecimal Default 0x03 internal sensor Bits 0 to 1: Threshold triggering • 0 = None • 1 = Low only • 2 = High only •...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 3.4.2 Network registers The list of registers below allows you to change the behaviour of the product application. This list is accessible in Provider mode following execution of the ATT63 Provider command.
Page 61
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 NOTE 1 : Le choix du Canal WMBUS (registre 200) permet une sélection du mode WMBUS : T, C, S ou R pour la fréquence 868. Le couple Canal (S200) et Format (S201) doit respecter le tableau ci-après :...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 4. DESCRIPTION OF THE FRAMES Le produit transmet des informations brutes en provenance des capteurs en utilisant le protocole Wireless M-BUS. Vous trouverez dans ce chapitre les informations permettant de décoder la trame Wireless M-Bus ainsi que les données utiles.
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 4.2.1.02 Status Byte The status byte is broken down in the following way: Alarm Status Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 2 to 3 5 to 6 Code Status PAYLOAD 0x11 Cf Status S324 S325 S326 S327 S333 0x11 0xA2 0x012C 0x0A 0x0032 0x05 0x06 Description of the frame: • Bytes 2 to 3: Registry 324, high threshold of the internal sensor, Most Significant Byte first •...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 4.2.4 Keep Alive frame This frame (0x30) is transmitted only in the event mode at the frequency defined by register 300. It contains the same fields as the data frame...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 4.2.5 Data Frame This frame (0x43) contains the values measured on the different sensors. Code Status PAYLOAD internal External Value read on the Value read on the 0x43 Cf Status...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 4.2.6 Summary of the conditions of the transmission of the uplink frames The table below summarizes the conditions of the transmission of the different uplink frames: Code Description Sending conditions...
6 seconds so as to confirm the start-up of the product. When the magnet is well detected, the green LED lights up for 1 second. Once the WMBUS TEMP unit validates its start-up, it immediately transmits status frames followed by a data frame (according the defined periodicity).
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 5.3. Closing the casing Once previous stages have been carried out, you can close the casing of the WMBUS TEMP Procedure: Make sure that the seal is properly positioned on the base Clip the electronic board onto the casing’s base.
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 6. INSTALLATION AND USE 6.1. Correct positioning of the product transceivers There are two key rules for optimising radio ranges. • The first one consists of positioning your product as high as possible.
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 To optimise fastening onto a tube or mast, we recommend you Pins remove the Rail-DIN locking/unlocking lever. To remove it, pull the lever down until the locking pins are opposite...
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 6.2.3 DIN-Rail fixing This system, integrated into the casing, enables the product to be fastened onto a standard 35 mm rail. • To fit the casing, place the upper inserts on the rail and lower the product to clip it into position.
Page 73
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 DEUTSCH Vorschriften 73 of 77...
Page 74
Recht vor, jederzeit und ohne Vorankündigung Änderungen an den Produktspezifi kationen und -beschreibungen vorzunehmen. adeunis® behält sich alle Rechte an diesem Dokument und den darin enthaltenen Informationen vor. Die Ver- vielfältigung, Nutzung oder Weiterverbreitung an Dritte ohne ausdrückliche Genehmigung ist streng untersagt.
Page 75
Programmiersprachen, unter Verwendung jeglicher elektrischer, mechanischer, magnetischer, optischer, manueller Geräte oder anderer Methoden, ist untersagt. adeunis® behält sich das Recht vor, ohne schriftliche Bekanntgabe und ohne ausdrückliches Verlangen seiner Kun- den die technischen Spezifi kationen oder Funktionen seiner Produkte zu ändern und sicherzustellen, dass die ihnen zur Verfügung gestellten Informationen gültig sind.
Page 76
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 UMWELTSCHUTZHINWEISE Es wurden alle überfl üssigen Verpackungsmaterialien vermieden. Wir haben uns bemüht, dass die Verpackung leicht in drei Materialarten getrennt werden kann: Pappe (Schachtel), expandiertes Polystyrol (Puff ermaterial) und Polyethylen (Tüten, Schaumstoff -Schutzlage). Ihr Gerät besteht aus recycelbaren Materialien, die im Falle einer Demontage durch ein Fachunternehmen wiederverwendet werden können.
Page 77
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0 GEBRAUCHSHINWEISE • Überprüfen Sie vor Benutzung des Systems, ob die in dessen Betriebsanleitung angegebene Versorgungsspan- nung mit Ihrer Stromquelle übereinstimmt. Falls nicht, wenden Sie sich an Ihren Lieferanten. • Stellen Sie das Gerät auf eine ebene, feste und stabile Oberfl äche.