PASS
ELECTRICAL EQUIPMENT
1- Gearmotor: power supply,
2- Photocell transmitter 2x0.5mm² cable
3- Photocell receiver 4x0.5 mm² cable
4- Antenna screened coaxial cable.
5- Frame 4x0.5mm² cable
6- Rack
7- Key selector 3x0.5mm² cable
8- 230 Vac flashing light signaller 2x0.75mm² cable
9- Omnipolar magnetothermal switch with minimum contact opening of 3 mm. Power supply line to the control
unit: 220-230V, 50-60Hz, 3x1.5mm²
(comply with the current standards).
ELECTRICAL EQUIPMENT
Operator
Type
Supply Voltage
Power adsorbed
Current adsorbed
Thermal cutout
Capacitor
Max speed
Max torque
Operating temperature
Degree of protection
Max leaf weight
Operating frequency (%)
Oil
Formula to calculate the
operating frequency
[22]
PRELIMINARY WARNINGS
Check that the gate structure is in conformity with the regulations in force and that leaf movement is linear without
friction.
Preliminary checks:
check that the gate structure is sufficiently robust. In any case, check that the weight and dimensions of the gate
fall within the limits of use of the operator;
check that the leaf can be moved manually without force (points of greatest friction) for the entire travel of the gate
during both opening and closing;
3x1.5mm²(PASS1200-1800) - 4x1,5mm² (PASS2500)
cable
(PASS1200-1800) - 380V,
PASS 1200
220/230Vac 50-60Hz
MAX 700W
MAX 3A
140°C
16µF
0,15 m/sec
50 Nm
-20°C + 60°C
IP 55
1200 Kg
90% (a 20°C)
A + C
%Fu =
A + C + P
cable (comply with the current standards)
50-60Hz, 5
PASS 1800
Irreversible electromechanical gearmotor
MAX 700W
MAX 3A
140°C
25µF
0,15 m/sec
60 Nm
-20°C + 60°C
IP 55
1800 Kg
60% (a 20°C)
GBD PH-02
A = Opening time
C = Closing time
x 100
P = Overall pause time
A+C+P = Time between two openings
UK
x1,5mm²
cable
(PASS2500)
PASS 2500
380Vac three-phase
MAX 750W
MAX 3A
140°C
-
0,15 m/sec
90 Nm
-20°C + 60°C
IP 55
2500 Kg
70% (a 20°C)
13