Muffler
Never use a machine that has a faulty muffler.
Regularly check that the muffler is securely attached to the
machine.
A blocked mesh will cause the engine to overheat and may
lead to serious damage.
Note! The mesh must be replaced if it is damaged. If the mesh
is blocked the machine will overheat and this will cause
damage to the cylinder and piston. Never use a machine with
a muffler that is in poor condition.
Never use a muffler if the spark arrestor mesh is missing
or defective.
The muffler is designed to reduce the noise level and to direct
the exhaust gases away from the operator. The exhaust gases
are hot and can contain sparks, which may cause fire if
directed against dry and combustible material.
A muffler equipped with a catalytic converter significantly
reduces the amount of hydrocarbons (HC), nitrogen oxides
(NO) and aldehydes in the exhaust fumes. Carbon monoxide
(CO), which is poisonous and odorless, is not however
reduced! Consequently, never work in an enclosed or badly
ventilated area. Good air circulation should always prevail
when working in snowy hollows, ravines or in confined
conditions.
32 –
Canadian
MAINTENANCE
Starter
!
Changing a broken or worn starter cord
Loosen the screws that hold the starter against the
crankcase and remove the starter.
Pull out the cord approx. 30 cm and hook it into the notch
in the rim of the pulley. Release the recoil spring by letting
the pulley rotate slowly backwards.
Undo the screw in the centre of the pulley and remove the
pulley. Insert and fasten a new starter cord to the pulley.
Wind approx. 3 turns of the starter cord onto the pulley.
Connect the pulley to the recoil spring so that the end of
the spring engages in the pulley. Fit the screw in the centre
of the pulley. Insert the starter cord through the hole in the
starter housing and the starter handle. Make a secure
knot in the end of the starter cord.
WARNING! When the recoil spring is wound
up in the starter housing it is under tension
and can, if handled carelessly, pop out and
cause personal injury.
Care must be exercised when replacing the
return spring or the starter cord. Wear
protective glasses and protective gloves.