INSTALLATION MANUAL
1.
INDOOR UNIT INSTALLATION
1.1
Installation place
The indoor unit should be installed in a location that meets the
following requirements:
- There is enough room for installation and maintenance.
The ceiling is horizontal, and its structure can endure the weight
-
of the indoor unit.
-
The outlet and the inlet are not impeded, and the influence of
external air is the least.
-
The air flow can reach throughout the room.
-
The connecting pipe and drainpipe could be extracted out easily.
-
There is no direct radiation from heaters.
>35mm
CAUTION
Keep indoor unit, outdoor unit, power supply wiring and
transmission wiring at least 1 meter away from televisions
and radios. This is to prevent image interference and noise
in those electrical appliances. (Noise may be generated
depending on the conditions under which the electric wave
is generated, even if 1 meter is kept.)
NOTE
All the pictures in this manual are for explanation purpose only.
There may be slightly different from the air conditioner you
purchased ( depend on model ). The actual shape shall prevail.
1.2
The dimension of the unit
C
>1000mm
MODEL
MUSTR-18/24-H8
MUSTR-30/36/48-H8
MUSTR-48/60-H8T
1.3 Install the main body
1
Installing
Please refer to the following figures for positioning 4 screw bolts.
Evaluate the ceiling construction and please install with 10
hanging screw bolts.
The handling to the ceiling varies from the constructions,
consult the construction person for the specific condition.
- Do keep the ceiling flat. Consolidate the roof beam to avoid
possible vibration.
- Cut off the roof beam.
- Strengthen the place that has been cut off, and consolidatethe
roof beam.
After the selection of installation location, position the refrigerant
pipes, drain pipes,indoor & outdoor wires to the connection
places before hanging up the machine.
The installation of hanging screw bolts.
42
A
D
A A
B B
C C
1068
675
235
1650
675
235
10 hanging screw bolts. (4 bolts)
O
Connecting point of
refrigerant pipe
(gas side)
Drain point
Connecting point of
refrigerant pipe
(Liquid side)
Hook
Unit:mm
D D
E E
983
220
1565
220
O