Télécharger Imprimer la page

mundoclima MUSTR-H8 Manuel D'installation Et L'utilisauter page 182

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 71
INFORMATION REQUIREMENTS
Model(s):
Outdoor side heat exchanger of air conditioner: Air
Indoor side heat exchanger of air conditioner: Air
Type: compressor driven vapour compression
If applicable: driver of compressor: electric motor
Item
Symbol
Rated cooling
P
rated,c
capacity
Declared cooling capacity for part load at given outdoor
temperatures T
and indoor 27°/19 °C (dry/wet bulb)
j
Tj = 35℃
Pdc
Tj = 30℃
Pdc
Tj = 25℃
Pdc
Tj = 20℃
Pdc
Degradation
co-efficient for air
C
conditioners (*)
Off mode
P
OFF
Thermostat-off
P
TO
mode
Capacity control
Sound power
L
WA
level,indoor/outdoor
If engine driven:
NO
Emissions of
x (**)
nitrogen oxides
GWP of the
refrigerant
SALVADOR ESCODA SA
PROVENZA 392 P2
Contact details
08025 BARCELONA (SPAIN)
+34 93 446 27 80
Information requirements for air-to-air air conditioners
Indoor unit(s)
Outdoor unit
Value
Unit
16,0
kW
16,000
kW
10,968
kW
6,967
kW
3,174
kW
0,25
dc
Power consumption in modes other than 'active mode'
0,01
kW
0,009
kW
variable
71/75
dB
mg/kWh
x
fuel
input GCV
kg CO
2 eq
2088
(100 years)
MUSTR-60-H8T
MUSTR-60-H8T
Item
Seasonal space cooling
energy efficiency
Declared energy efficiency ratio or gas utilisation
efficiency/auxiliary
energy factor for part load at given outdoor temperatures T
Tj = 35℃
Tj = 30℃
Tj = 25℃
Tj = 20℃
Crankcase heater mode
Standby mode
Other items
For air-to-air air
conditioner: air flow
rate, outdoor
measured
182
Symbol
Value
Unit
η
241,0
%
s,c
EERd
230,9
%
EERd
441,9
%
EERd
712,5
%
EERd
1321,4
%
P
0,000
kW
CK
P
0,01
kW
SB
7200
m3/h
j

Publicité

loading