The Digital Control Board system is an intricate and valuable piece of technology. For protection from power surges and electrical
shorts, consult the wire diagram below to ensure your power source is sufficient for the operation of the unit.
PB – ELECTRIC REQUIREMENTS
110-120 V, 60 Hz, 275 W, 3-PRONG GROUNDED PLUG
NOTE: Electrical components, passed by product safety testing and certification services, comply
with a testing tolerance of ± 5-10 percent.
FUEL INPUT
GROUNDED
RATING:
POWER CORD
VW-1, 105°C/221°F,
2.48 LB/H
18-3 STANDARD CSA
(1.12 KG/H)
BURN POT
INDEX
W : WHITE
Y : YELLOW
P : PURPLE
R : RED
K : BLACK
G : GREEN
S : SILVER
22
ELECTRICAL WIRE DIAGRAM
K
K
W
W
G
GROUND
W
P
W
W
W
W
IGNITER ASSEMBLY /
HD CARTRIDGE HEATER
120V, 200W
LOCATE AND REMOVE
THE FOUR SCREWS
OF ACCESS PANEL ON
UNDERSIDE OF UNIT
W
GRILL PROBE
CONNECTOR
FAST-BLOW
FUSE
P
Y
P
Y
R
W
W
R R
AUGER MOTOR
& FEED SYSTEM
120V, 60Hz,
2 RPM MOTOR
GRILL
S
PROBE
CONTROL BOARD
Y
Y
Y
DRAFT FAN
120V, 60Hz,
1 PHASE