GS
≥ 0,8 m
≤ 2,7 m
GW
Fine gravel/
grit
Standard installation conditions for the
RAUSIKKO Box S *)
Installation conditions which deviate from this – in particular deeper
installation depths – require an individual assessment and are to be clarified
with the REHAU technical applications department.
The approval of these alternative installation conditions is ultimately given
by the company commissioned with the installation and/or the building
supervisor or specifier.
The specifications of the guidelines for standardising the roadbed (Issue
2012) under classified road surfaces are to be observed.
*)
Native soil of soil types G1 to G3 according to DWA work sheet A 127 (friable and
non-cohesive soils and also cohesive mixed soils and silts)
SLW
60
≤ 4,0 m
0,1 m
≥ 1,0 m
GS
≥ 0,8 m
≤ 2,7 m
GW
Fine gravel/
grit
Standard installation conditions for the
RAUSIKKO Box H*)
SLW
60
≤ 6,0 m
0,1 m
≥ 1,0 m
EN