4-1. Front Panel Controls
1
Power Switch
Use switch to turn unit On/Off.
2
Output Indicator Light
When unit is first energized this indicator light
1
4-2. Mode Switch Settings
NOTE
Mode Switch Setting
Lift-Arc TIG
TIG
7018 (Soft)
7018 (Stiff)
6010 (Soft)
6010 (Stiff)
SECTION 4 – OPERATION
energizes for 4 seconds and remains on in all
positions except Remote Tig.
3
Process Control (see Section 4-2)
4
Amperage Control (see Section 4-4)
2
The Stick modes provide the Adaptive Hot Start feature, which automatically
increases the output amperage at the start of a weld should the start require it. This
eliminates electrode sticking at arc start.
Process
GTAW With Lift-Arc Start – See Section 4-3
GTAW With HF Unit, Pulsing Device, Or Remote Control
SMAW When A Soft Arc Characteristic Is Desired
SMAW When A Stiff Arc Characteristic Is Desired
SMAW When A Soft Arc Characteristic Is Desired
SMAW When A Stiff Arc Characteristic Is Desired
5
High Temperature Shutdown Light
When unit is first energized this indicator
light illuminates for approximately 4 seconds
to provide visual confirmation that the light is
functioning properly (see Section 2-2).
5
4
3
208 262
Output On/Off Control
Electrode Hot
At Remote 14
Electrode Hot
Electrode Hot
Electrode Hot
Electrode Hot
OM-208 474 Page 15