STUDER Innotec
3.3
Connections
3.3.1 General instructions on connecting
− The cable connection on the terminals AC INPUT / AC OUTPUT / 16A 230VAC
are carried out with a screwdriver Nr.1 and the connection on the SOLAR
terminal with a screwdriver Nr.2.
− The conductor cross section on the terminals AC INPUT / AC OUTPUT / 16A
230VAC of the connecting cable must be minimum 2.5mm2.
− All connecting cables and also the mounted battery cables, must be fixed with
strain relief clamps.
− The COMPACT is delivered with battery cables already connected.
− The battery cables must never be extended. If the extension is unavoidable then
the conductor cross section must be elevated accordingly.
− To protect the battery cable, a fuse corresponding to the conductor cross
section must be fixed directly on to the battery.
− All cables must be tightly screwed in place. For safety, a yearly control is
recommended. In mobile installations control must be carried out more often.
− Connecting must be done by qualified personnel. Material such as cable,
connectors and distribution boxes, fuses etc. used in the installation must
comply with the respective valid low-voltage installation rules and regulations.
3.3.2 Protection cover of the terminals connections
The protection is available as an option (Order ref.
CFC-01) to avoid accidental and hazardous contact
on the terminals 230Vac if the unit is mounted in a
non restricted access area.
It is delivered with strain relief clamps for the cable.
COMPACT V6.4
COMPACT
11/85