For the periodic maintenance of the pump, unplug the pump from the
electric socket and then remove the pump from water.
1) Lift the plastic ring of the pump's volute pulling the tab outwards
(Pic.6)
2) Remove the ring (Pic.7)
3) Remove the volute of the pump by turning and simultaneously
pulling forward (in the case of fouling this may take more pressure).
4) Pull out the complete rotor set (Pic.8)
5) Rinse each part with water, using a soft brush to remove the
deposit.
6) Then assemble everything in the inverse order.