OPERATION
PM400SS
Blower Switch:
A rotary 4-position knob controls the blower speed
(Off - low speed - medium speed - high speed) .
Light Switch:
A rotary 2-position knob turns the LED lights ON and OFF .
BBN2243SS, BBN2303SS
ON/OFF Blower Push Button: When blower is OFF, push
this button to turn ON the blower at the last selected speed .
HQ0034
Push this button again to turn OFF the blower .
NOTE: If there is no speed selected (all blower speed push
buttons up), the blower will not turn ON . In that case,
press on the desired speed level push button to activate
the blower .
Blower Speed Level Push Buttons:
When blower is ON, change the blower speed by pressing
HQ0035
the push button corresponding to the desired speed: one line
for LOW, two lines for MEDIUM and three lines for HIGH
speed .
ON/OFF Light Push Button: When lights are OFF, push
HQ0036
once on this button to turn ON the lights . Push this button
again to turn OFF the lights .
ALL UNITS
HEAT SENTRY™
Your unit is equipped with a HEAT SENTRY™ thermostat .
This thermostat is a device that will turn on or speed up the blower
if it senses excessive heat above the cooking surface .
1) If blower is OFF - it turns blower ON to HIGH speed .
2) If blower is ON at a lower speed setting - it turns blower
up to HIGH speed .
When the temperature level drops to normal, the blower will return
to its original setting .
!
WARNING
The HEAT SENTRY thermostat can start the blower
even if the hood is turned OFF . When this occurs, it
is impossible to turn the blower OFF with its switch .
If you must stop the blower, set the main power
switch (located behind the filters, on inner side of
the unit faceplate) in OFF position (if it is possible to
do so safely) . See inset in FIG . 32 .
Blower Switch
HC0106
Knob
HC0107
HD1361
Light Switch
Knob
FIG. 32
17