PREPARE THE UNIT
a
ll inStallationS
1 . If present, remove all protective polyfilm from the unit and/
or parts .
2 . Remove the grease filter(s) by pushing down on latch tab
and tilting the filter(s) downward (FIG . 15) . Set aside the
filter(s) .
3 . Disassemble the electrical compartment cover (grey part
in FIG . 16) from inside the unit by removing its retaining
screw . Remove the parts bag behind the cover . Set aside
the parts bag and the cover along with its screw .
4 . Punch out one of the two knock-out holes . Install an
appropriate 7/8" diameter strain relief (not included, grey
part in FIG . 17) .
NOTE: The HCK44 cord connection kit (optional) can
be used instead of the house power cable . Refer to the
instruction packed with the HCK44 cord connection kit .
h
orizontal exhauSt inStallation only
5 . Unplug the blower cable from its connector on faceplate .
Disassemble the faceplate from the unit by removing its
4 retaining screws (two per side, circled in FIG . 18) . Set
aside the faceplate along with its screws .
6 . Remove the 6 screws (2 per side and 2 in front) retaining
the blower support plate to the top of the unit (FIG . 19) .
Carefully lift out and set aside the blower with its support
plate . The blower will be reinstalled later in the unit .