1
2
3
46
5-17
5-18
5-18b
5-19
5-20
5-21
Operation
5.9
Weight application
The following weight types and application
methods are available:
- Clip-on weights.
• Always apply by hand at 12 o'clock (Figure
5-17).
• The tab should be fi tted on the rim edge. Use the
weight pliers to correctly position it.
- Stick-on weights.
• With Laser Pointer enabled, apply by hand at
approx. 5 o'clock, where indicated by Laser Pointer,
in case of Alu 1P, Alu 2P, Alu 3P, Alu 2 and Alu 3
(Figure 5-16).
• With Laser Pointer disabled. Apply with arm gauge,
in case of Alu 1P, Alu 2P and Alu 3P (Figure 5-18b).
• Apply by hand at 12 o'clock in all other cases
(Figure 5-18).
Note: With STATIC balancing mode, always apply
the weight at 12 o'clock on the rim centre line. If
not possible, split the weights evenly and apply on
another surface of the rim (symmetrical to the rim
centre line).
Note: In STATIC balancing modes, only the left
hand display is used.
After wheel run, look at the rotation indicators for
the left plane of the wheel (1, Fig. 5-19):
• Slowly rotate the wheel by hand (e.g.
anticlockwise).
As the correct angle position is reached a further
indicator lights up.
When all the indicators are ON (2, Fig. 5-20), the
WAP indicator will also light up (3-Figure 5-20).
Note: When the correct angle is reached all the
rotation indicators should be ON.
If the wheel has been pushed too far, only the
indicators of the other half will come ON (Figure
5-21).
The weight to be applied in that plane is shown on
the display.
...