Introduction
Thank you for purchasing this Silverline product. This manual contains information necessary
for safe and effective operation of this product. This product has unique features and, even
if you are familiar with similar products, it is necessary to read this manual carefully to
ensure you fully understand the instructions. Ensure all users of the product read and fully
understand this manual. Keep these instructions with the product for future reference.
Description of Symbols
The rating plate on your product may show symbols. These represent important information about
the product or instructions on its use.
Wear hearing protection
Wear eye protection
Wear breathing protection
Wear head protection
Wear hand protection
WARNING: To reduce the risk of injury, user must read instruction
manual
Caution!
DO NOT use with compressed gas cylinders!
Conforms to relevant legislation and safety standards.
Environmental Protection
Air tools should not be disposed of with household waste. They contain traces of
oil and other lubricants. Please recycle where facilities exist. Check with your local
authority or retailer for recycling advice.
Technical Abbreviations Key
n
0
psi
bar
L/min
cfm
Ø
min
-1
BSP
dB(A)
m/s
2
6
No load speed
Pounds per square inch
Metric unit of pressure
Litres per minute
Cubic feet per minute
Diameter
Revolutions or reciprocations per minute (rpm)
British Standard Pipe (thread)
Decibel sound level (A weighted)
Metres per second squared (vibration
magnitude)
Original Instructions
Specification
Working pressure: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.0 – 7.5bar (60–108psi)
Maximum pressure: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.3bar (120psi)
Air inlet:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1⁄4" BSP quick connector
Nail size: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Gauge, 10–32mm
Nail capacity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100pce
Staple size: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Gauge, 16-32mm (type 90 & A type)
Staple width:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.7mm
Staple capacity:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100pce
Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3kg
As part of our ongoing product development, specifications of Silverline products
may alter without notice.
Sound and vibration information:
Sound pressure L
: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86.4dB(A)
PA
Sound power L
: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99.4dB(A)
WA
Uncertainty K:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5dB(A)
Weighted vibration a
: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.55m/s
h
Uncertainty K:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.19m/s
The sound intensity level for the operator may exceed 85dB(A)
and sound protection measures are necessary.
Fastener Tool Safety Warnings
WARNING: Read and understand the safety instructions before installing, operating, repairing,
maintaining, cleaning, changing accessories on, or working near this tool. Failure to do so can result
in serious injury.
Save all warnings and instructions for future reference.
WARNING: This appliance is not intended for use by persons (including children) with reduced
physical or mental capabilities or lack of experience or knowledge unless they have been given
supervision or instruction concerning use of the tool by a person responsible for their safety.
Children must be supervised to ensure that they do not play with the tool.
• Only qualified and trained users should install, adjust, or use the tool.
• Do not modify the tool. Modifications can reduce the effectiveness of safety measures and
increase the risks to the user.
• Do not discard the safety instructions; give them to the user.
• Do not use the tool if it has been damaged.
• Inspect the tool periodically to verify that the ratings and markings required by ISO 11148
(detailed in the Description of Symbols) are legibly marked on the tool. The user (and employer
if appropriate) should contact the manufacturer to obtain replacement marking labels when
necessary.
• Compressed air can cause severe injury.
• Always disconnect the tool from the air supply when not in use.
• Always disconnect the tool from the compressed air supply before changing accessories, making
adjustments and/or repairs and when moving away from an operating area to a different area.
• Keep fingers away from trigger when not operating the tool and when moving from one
operating position to another.
• Never direct compressed air at yourself, others or animals.
• Whipping hoses can cause severe injury. Always check for damaged or loose hoses or fittings.
• Never carry or drag an air tool by its hose.
• When using air tools, do not exceed the maximum operating pressure.
• Inspect tools and accessories before each use. Do not use if damaged or excessively worn.
• Air tools should only be powered by compressed air at the lowest pressure required by the task to
reduce noise and vibration and minimise wear.
• Never use pure oxygen or combustible gases to power an air tool. Air tools are not designed for
these power sources and their use creates a fire and explosion hazard.
• Be aware that air tools may become cold during use, affecting grip, control and susceptibility to
vibration-related injury.
IMPORTANT: Even when this tool is used as prescribed it is not possible to eliminate all residual risk
factors. If you are in any doubt as to the safe use of this tool, do not use it.