Télécharger Imprimer la page

STERWINS 900 JET-3 Notice De Montage, Utilisation Et Entretien page 200

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 4
the suction-hose set yourself using a standard adapter and a clamp.
Attach the filter to the wall. Make sure that the vibrations of the pump do not damage this
installation (flexible connection is strongly recommended)
FR
4.3 FIRST USE
ES
PT
Pay particular attention using the machine for the first time : focus and dedicate all your attention to this
IT
first use.
Setting up your pump
EL
• Place the pump on flat firm surface to ensure safe operation.
• Remove the connectors caps from the connectors and store them.
Connecting the suction hose
PL
• Screw the standard connectors onto the suction connector.
• Assemble the suction hose using a standard connector and clamp. Make sure the assembly is tight
RU
enough as a leaking suction hose will draw in air instead of water.
• If the water is not so clear, add a filter between the suction connector and suction hose.
KZ
UA
RO
EN
FR
ES
PT
• Position the suction hose so that it rises from the water withdrawal point to the pump. Avoid positioning
IT
the suction hose higher than the pump, as this would delay the escape of air bubbles and impede the
priming process.
EL
• The end of the check valve should be low enough in the water to ensure that if the water level falls, the
pump will not run dry.
• A leaking suction hose will draw in air instead of water. Please make sure the clamp is properly tightened.
PL
• For suction heights exceeding 3 m we recommend securing the suction-hose (e.g. by fastening it to a
wooden post). This relieves the pump of the weight of the suction hose.
• Install the intake and discharge lines in such a way that they do not place the pump under any
RU
mechanical strain.
Priming the pump
KZ
First, unscrew the filling plug to remove air from the pump during filling.
Fill the pump with clear water via discharge connector. Filling must be done slowly so that the air
contained in the pump is completely expelled. Fill to overflow and put back the filling plug. As this is
UA
not an auto-priming pump, the suction pipe will also need to be filled. To save time when filling, you
can detach the suction pipe set and fill it directly (by submerging the suction pipe in water, for example)
before connecting the pump.
RO
Depending on the suction height and the amount of air in the suction hose, priming can take anywhere
between 1 minute to 5 minutes. If it takes longer than this, the pump should be refilled with water.
WARNING ! Read the « SAFETY INSTRUCTION » section at the
beginning of this manual including all text under subheading
therein before using this product.
Risk of damage to the pump!
If without filter: unwanted particles (sand, stones, etc.) will
cause damages to the pump. Any damage caused in this way
will not be covered under our warranty
Risk of damage to the pump!
The hose adapters on the suction and discharge connectors
must only be tightened by hand to avoid damage to
connectors. If water leaking at the connector, seal the joint
illustration 2.4 to 2.6
13
200
R
K
U
R
E

Publicité

loading