Instruction Manual
6.4.3
DA-mode / Double acting
Abb. 19
4/2-way or 5/2-way solenoid valves are used to control double acting actuators
(DA).
They can be mounted either directly to the actuator via a Namur connector plate
or via valve clusters.
7
Commissioning
NOTICE
Higher control pressures or mechanical aids or cavitation
Damage to the diaphragm valve.
Use mentioned control pressure to actuate the diaphragm valve.
Use valve only at optimal control operation conditions.
Check that all valves are in the required open or closed position.
Fill the piping system and deaerate completely.
7.1
Pressure testing
Make sure that the test pressure may not exceed the PN of the diaphragm valve.
Diaphragm valve pressure testing is subject to the same regulations as the
piping system.
When pressure exeeds 10 bar the controll pressure must be throttled by exhaust
air (adjust actuating time to approx. 3 s)
The valves and connections should be checked for a tight seal during the
pressure test.
52
Commissioning