4.2.1 m
Achine
No reaction to the start signal: Check for correct function-
ing of inductive sensors.
4.2.2 r
Apid trAVel
Rapid travel functions only sluggishly, for not at all: Check
air compression value (5-7bars). Check air line for kinks.
Rapid travel functioning, but not followed by drilling travel:
Check adjustment of braking cylinder.
4.3 r
epAir
If despite strict observance of the manufacturing and test-
ing method the machine should happen to fail, it must be
repaired by an authorized SUHNER agency.
In all orders to the manufacturer please indicate the ma-
chine serial number (1).
4.4 w
ArrAnty
In the event of the tool being improperly handled, used
for purposes for which it is not intended and/or of the ser-
vice and maintenance instructions not being observed by
non-authorized persons, no warranty shall be in effect for
damages/consequential damages.
Complaints can only be honored if the machine is re-
turned in the undisassembled condition.
4.5 s
tOrAge
Temperature range: 20°C to +50°C
Max. relative air humidity: 90% at +30°C, 65% at +50°C
4.6 d
/ e
ispOsAl
nVirOnmentAl cOmpAtiBility
This machine consists of materials which can be dis-
posed of in a recycling process.
Before disposal, render the machine unusable.
Do not throw the machine into the garbage collec-
tion.
According to national regulations this machine
must be recycled in an environmentally-friendly manner.
31