1. N
1.1 g
enerAl nOtes On sAFety
This operation manual is applicable for the partly com-
pleted machinery BEM 12.
The machine may only be handled by personnel
who are qualified.
1.2 u
se OF the mAchine FOr purpOses FOr
which it is intended
The partly completed machinery is suitable for all machin-
ing operations needing axial force and torque like drill-
ing, reverse drilling, chip breakage, countersinking, and
reverse countersinking. It is specifically ideal for plant
construction.
The partly completed machinery may only be used in a
non-explosive environment where there are no flammable
liquids, gases or dusts!
1.3 i
ncOrrect use
All uses other than those described under section
1.2 are regarded as incorrect use and are there-
fore not admissible.
1.4 d
eclArAtiOn OF incOrpOrAtiOn
The manufacturer SUHNER Schweiz AG of Industri-
estrasse 10, CH-5242 Lupfig, hereby declares for the
partly completed machinery (see reverse side for type and
serial no.) that the following fundamental requirements of
the Directive 2006/42/EC are applied and fulfilled in ac-
cordance with Annex I: 1.1.2, 1.1.3, 1.1.5, 1.2.1, 1.2.2, 1.3.7,
1.3.8.1, 1.5.1, 1.5.4, and 1.6.1. Technical documentation
was generated for the partly completed machinery in ac-
cordance with Annex VII of the Machinery Directive. Docu-
ment Agent: M. Maglione. Authorised sites are provided
with this technical documentation in paper or electronic
form on justified request. This partly completed machin-
ery may be put into operation only when the machine in
which the partly completed machinery is to be incorpo-
rated has been ascertained to fulfil the conditions under
the Machinery Directive. CH-Lupfig, 09/2023.
M. Maglione/Division manager
2. c
2.1 s
AFety instructiOns tO Be OBserVed On
cOmmissiOning
Before all work on the machine, it must
first be disconnected from the power sup-
ply.
Only a qualified person familiar with the safety regulations
26
S
oTES oN
aFETy
ommISSIoNINg
may start up the machine.
Always conduct test runs without workpieces.
Check the sense of rotation before starting the machine.
The operator must make sure that the components are
integrated and operate safely in the machine.
Only a qualified person may connect the electrical power
supplies in accordance with the local regulations.
The local grounding regulations must be observed and
implemented, and this implementation inspected.
Do not start the machine until the spindle has come to a
stop.
Use only suitable tools, and never modify tools for an ap-
plication they have not been designed for.
After transport, all electrical and mechanical connections
must be examined for damage and loosening, and any
remedial measures taken.
The machine's working area must be unobstructed and
secured against unauthorized access.
When internal cooling is used, please observe the instal-
lation instructions issued by the manufacturers of the at-
tachment and rotating union.
The motor's and spindle's sense of rotation may be
checked only when there is no tension in the belt. Cor-
recting a wrong sense of rotation involves swapping over
any two of the phase conductors.
The motor cable's shielding must be connected to the
motor housing over a large area at the terminal board.
2.2 A
ssemBly instructiOns
Maximum admissible machine fastening error.
The machine is fastened at the bores provided in
the housing.
Screws of quality grad 8.8 must be used. The starting tor-
que for the holding down bolt is maximum 30Nm.
Connect the cables only after the machine has
been completely installed.