2.3 c
Onnecting the pOwer tO the mAchine
2.3.1 m
OtOr
Before the power is connected to the motor, position the
terminal stripe jumpers according the mains power volt-
age (230 V, 400 V, 460 V).
After the power has been connected to the motor
the direction of rotation of the working spindle has
to be checked. If the direction of rotation is incorrect, re-
verse the direction by exchanging any two power wires.
2.3.2 p
rOximity switch
The proximity switches are supplied (feed voltage 24
VDC) by a separate power supply or the higher level con-
troller. The machine is provided with inductive or pneu-
matic signaling elements alternatively.
Loosen the screws and remove the cover.
The electronic or pneumatic proximity switches are set at
the factory.
c
OnnectiOn eletric
Blue
Brown
Black
Voltage
Output current
Output
c
OnnectiOn pneumAtic
Connection P
Connection A
Feed pressure at P
Signal pressure range at A
2.3.3 p
neumAtic AdVAnce
Attach air hoses (polyurethane hoses Di=4 mm, max.
pressure 7 bars, -35 to 60 °C ) to the installed pneumatic
connections.
For the quality of compressed air, see point 2.6!
w
ithOut chip remOVAl
Stroke «forward» (1). Stroke «back» (2).
minus
plus
control pulse
12-24V DC
max. 200mA
PNP
black
yellow
0-8bar
0 - feed pressure
27