6.2

Filter replacement

The buzzer emits an acoustic signal when the airflow is too
low.
Make sure that:
- the shut-off damper is open
- the extraction arm is not fully folded
When the buzzer still continues, you must replace the filter
cassette(s).
As the pre filter is smaller and becomes more quickly saturated
than the HEPA filter, you can replace the pre filter cassette
several times before you finally need to replace the HEPA filter
cassette.
Personal protective equipment (PPE)
Wear respiratory protection and protective
gloves when you replace the filter
cassettes.
WaRNiNG
Do not replace the filter cassettes while the fan is
running.
WaRNiNG
Do not shake out or (vacuum) clean the used filter
cassettes to avoid the release of particles.
6.2.1
Pre filter cassette
To replace the pre filter cassette, do the following.
Fig. 6.1
• De-energize the unit.
• Open the back door (B).
• Remove the pre filter cassette (A).
• Dispose of the used filter cassette in accordance with state
or local regulations.
• Put a new pre filter cassette in the unit. Make sure that the
arrow on the frame points downwards
• Close and lock the door.
Fig. 6.1 Replacement of the pre filter cassette
When the buzzer continues to beep after you have
replaced the pre filter cassette, it is time to replace
the HEPA filter cassette.
6.2.2
HEPA filter cassette
To replace the HEPA filter cassette, do the following.
Fig. 6.2
• De-energize the unit.
• Open the back door (C).
• Remove the pre filter cassette.
• Slightly lift and remove the HEPA filter cassette (D).
4. The arrow indicates the airflow direction
0000111659/150418/B MobileGo
.
4
A
B
• Dispose of the used HEPA filter cassette in accordance with
state or local regulations.
• Put a new HEPA filter cassette in the unit. The side pins (A)
exactly fit in the slits (B).
• Put the pre filter cassette back in the unit. Make sure that
the arrow on the frame points downwards
• Close and lock the door.
A
Fig. 6.2 Replacement of the HEPA filter cassette
6.3
arm adjustment
If the extraction arm, or a part of it, does not stay in the
desired position, you must adjust the friction.
6.3.1
Hose tube arm (EconomyArm)
• Determine which joint needs more or less friction.
• Loosen the hose tube to get access to the hinges.
• Pull the arm in a horizontal position.
• Adjust the friction; refer to Fig. V on page 52 for the
adjustment points.
6.3.2
Metal tube arm (KUA)
• Determine which joint needs more or less friction.
• Loosen the hose at that position to get access to the hinge.
• Pull the arm in a horizontal position.
• Adjust the friction; refer to Fig. V on page 52 for the
adjustment points.
7

TRoubLEShooTiNG

If the unit does not function (correctly), consult the checklist
below to see if you can remedy the error yourself. Should this
not be possible, contact your supplier.
WaRNiNG
Obey the safety regulations that are written in
chapter 3 when you carry out the activities below.
5. The arrow indicates the airflow direction. An incorrectly placed pre filter
cassette affects the filter lifetime.
.
5
B
C
D
EN - 8

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mobilegoplus

Table des Matières