WaRNiNg
To keep the welding fume away from the breathing
zone of the welder, make sure that all fume is
extracted through the hood.
• Put the unit off approx. 20 seconds after you have finished
welding.
When the airflow is too low during use, the service indicator
(ref. Fig. 5.1B) is on. Refer to chapter 7 to find the possible
cause and the solution.
aTTENTioN
If you do not replace the pre filter cassette and/or
the HEPA filter cassette in time, the airflow
(extraction capacity) further drops.
6
MaiNTENaNcE
6.1
periodic maintenance
The product has been designed to function without problems
for a long time with a minimum of maintenance. In order to
guarantee this some simple, regular maintenance and cleaning
activities are required which are described in this chapter. If
you observe the necessary caution and carry out the
maintenance at regular intervals, any problems occurring will
be detected and corrected before they lead to a total
breakdown.
WaRNiNg
Overdue maintenance can cause fire.
The indicated maintenance intervals can vary depending on
the specific working and ambient conditions. Therefore we
recommend to thoroughly inspect the complete product once
every year beside the indicated periodic maintenance. For this
purpose contact your supplier.
component
action
Filter unit
Housing
Clean the outside with a non-
aggressive detergent
Clean the inside with an industrial
vacuum cleaner and remove dust
from the filter compartment
Check sealing material of the door.
Replace if necessary
Extraction fan
Check for encrusted particles. Clean if
necessary
Mains cord
Check for damage. Repair or replace
if necessary
Extraction arm
Tubes
Clean the outside with a non-
aggressive detergent
Clean the inside thoroughly
Flexible hoses
Check for cracks or damages. Replace
if necessary
Hood
Check the movement of the hood. If
necessary, adjust the friction; refer to
section 6.3
Arm
Check horizontal, vertical and
movement
diagonal arm movement. If
necessary, adjust the friction; refer to
section 6.3
0000115336/010518/0 MobileGo
Frequency:
every X
months
X=6
X *)
X
X
X
X
X
60Hz
plus
component
*) Before every use
6.2
Filter replacement
The service indicator (red LED) is on when the airflow is too
low.
Make sure that:
- the shut-off damper is open
- the extraction arm is not fully folded
When the service indicator stays on, you must replace the
filter cassette(s).
As the pre filter is smaller and becomes more quickly saturated
than the HEPA filter, you can replace the pre filter cassette
several times before you finally need to replace the HEPA filter
cassette.
WaRNiNg
Do not replace the filter cassettes while the fan is
running.
WaRNiNg
Do not shake out or (vacuum) clean the used filter
cassettes to avoid the release of particles.
6.2.1
Pre filter cassette
To replace the pre filter cassette, do the following.
Fig. 6.1
• De-energize the unit.
• Open the back door (B).
• Remove the pre filter cassette (A).
• Dispose of the used filter cassette in accordance with state
or local regulations.
X =12
• Put a new pre filter cassette in the unit. Make sure that the
arrow on the frame points downwards
X
• Close and lock the door.
X
X
X
Fig. 6.1 Replacement of the pre filter cassette
When the service indicator stays on after you have
replaced the pre filter cassette, it is time to replace
the HEPA filter cassette.
4. The arrow indicates the airflow direction
action
personal protective equipment (ppE)
Wear respiratory protection and protective
gloves when you replace the filter
cassettes.
Frequency:
every X
months
X=6
X =12
.
4
A
B
EN - 7