uSE

WaRNiNG!
Fire hazard! Do not use the product for polishing
applications in combination with grinding, welding or
any other application that generate sparks.
Refer to chapter 3 / Safety instructions / Use.
5.1

Control panel

The unit contains the following controls and indicators:
Fig. 5.1
A Tumbler switch 0-1 with green LED
B
Buzzer (service indicator)
Fig. 5.1 Controls and indicators
5.2
use
Since it concerns a mobile unit, you can use it at any desirable
place. For optimal results you must place the unit as close as
possible to the source of pollution.
• Position the hood of the connected extraction arm at
400-800 mm (16-32 in.) from the source of pollution. Refer
to Fig. III on page 51 for the correct position.
• Make sure that the shut-off damper (ref. Fig. 2.1A) is open.
• Put the unit on (ref. Fig. 5.1A).
• Start welding.
• When the welding position changes, move the hood to the
correct position in relation to the weld.
0000111659/150418/B MobileGo
F
E (2x)
G
H
A
B
WaRNiNG
To keep the welding fume away from the breathing
zone of the welder, make sure that all fume is
extracted through the hood.
• Put the unit off approx. 20 seconds after you have finished
welding.
When the airflow is too low during use, the buzzer (ref. Fig.
5.1B) emits an acoustic alarm. Refer to chapter 7 to find the
possible cause and the solution.
aTTENTioN
If you do not replace the pre filter and/or the HEPA
filter cassette in time, the airflow (extraction
capacity) further drops.
6

MaiNTENaNCE

6.1

Periodic maintenance

The product has been designed to function without problems
for a long time with a minimum of maintenance. In order to
guarantee this some simple, regular maintenance and cleaning
activities are required which are described in this chapter. If
you observe the necessary caution and carry out the
maintenance at regular intervals, any problems occurring will
be detected and corrected before they lead to a total
breakdown.
WaRNiNG
Overdue maintenance can cause fire.
The indicated maintenance intervals can vary depending on
the specific working and ambient conditions. Therefore we
recommend to thoroughly inspect the complete product once
every year beside the indicated periodic maintenance. For this
purpose contact your supplier.
Component
action
Filter unit
Housing
Clean the outside with a
non-aggressive detergent
Clean the inside with an industrial
vacuum cleaner and remove dust
from the filter compartment
Check sealing material of the
door. Replace if necessary
Extraction
Check for encrusted particles.
fan
Clean if necessary
Mains cord
Check for damage. Repair or
replace if necessary
Extraction arm
Tubes
Clean the outside with a
non-aggressive detergent
Clean the inside thoroughly
Flexible
Check for cracks or damages.
hoses
Replace if necessary
Hood
Check the movement of the hood.
If necessary, adjust the friction;
refer to section 6.3
Arm
Check horizontal, vertical and
movement
diagonal arm movement. If
necessary, adjust the friction;
refer to section 6.3
*) Before every use
Frequency:
every X months
X=6
X =12
X
X
X
X
X *)
X
X
X
X
X