Specifications
Installation Requirements
The speed oven can be installed in a standard or flush inset
application.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
For flush inset installations, a minimum 3 mm reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT
60 cm Model
76 cm Model
TRIM OVERLAP
60 cm MODEL
76 cm MODEL
Top
5 mm
Bottom
0 mm
Sides
18 mm
Electrical Requirements
Installation must comply with all applicable electrical
codes and be properly grounded (earthed).
Locate the electrical supply as shown in the illustrations
on the following page. The receptacle may also be located
in an adjacent cabinet within reach of the power cord. A
separate circuit, servicing only this appliance is required. A
ground fault circuit interrupter (GFCI) is not recommended
and may cause interruption of operation.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
MIN
57 kg
Power Cord
57 kg
5 mm
0 mm
98 mm
RATING PLATE
Rating plate location
IMPORTANT NOTE: Connection of this appliance should
be through a fused connection unit or a suitable isolator,
which complies with national and local safety regulations.
The on/off switch should be easily accessible after the
appli ance has been installed. If the switch is not acces-
sible after installation (depending on country) an additional
means of disconnection must be provided for all poles of
the power supply. When switched off there must be an all
pole contact gap of 3 mm in the isolator switch. This 3 mm
contact dis connect gap must apply to any isolator switch,
fuses and/or relays according to EN60335.
220-240 V AC, 50 Hz
2550 W
1.2 m