BTL7-V50D-M _ _ _ _ -P-C003
Transducer in a Profile Housing
6
Technical data
6.1
Accuracy
The specifications are typical values for BTL7-V50D... at
24 V DC and room temperature, with a nominal length of
500 mm in conjunction with the BTL5-P-3800-2,
BTL5-P-4500-1, BTL5-P-5500-2
BTL6-A-3801-2
, BTL5-F-2814-1S, BTL5-T-2814-1S,
1)
BTL5-M-2814-1S or BTL5-N-2814-1S magnet.
The transducer is fully operational immediately, with full
accuracy after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Position resolution
Non-linearity with a constant distance
between the magnet and profile:
Nominal length ≤ 5500 mm
Nominal length > 5500 mm
Hysteresis
Repeat accuracy
Temperature coefficient
2)
Velocity resolution
Min. detectable velocity
Max. detectable velocity
6.2
Ambient conditions
Operating temperature
Storage temperature
Humidity
Shock rating
Continuous shock
per EN 60068-2-27
4)
Vibration
per EN 60068-2-6
4)
Degree of protection per
IEC 60529
Connector C003 (when
attached)
12
english
, BTL6-A-3800-2
,
1)
1)
1 µm
±30 µm
±0.02 % FS
≤ ±10 µm
≤ ±5 µm
(typ. ±2.5 µm)
≤ 18 ppm/K
0.1 mm/s
1 mm/s
10 m/s
3)
−40°C...+85°C
−40°C...+100°C
< 90%, non-condensing
150 g/6 ms
150 g/2 ms
20 g, 10...2000 Hz
IP67
6.3
Supply voltage (external)
Voltage, stabilized
5)
Ripple
Current draw (at 24 V DC)
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength
(GND to housing)
6.4
Output
Short-circuit resistance
6.5
Dimensions, weights
Housing height
Nominal length
Weight (depends on length)
Housing material
6.6
Maximum sampling rate f
At nominal length
0050...0250 mm
0251...0600 mm
0601...1300 mm
1301...2700 mm
2701...5500 mm
5501...7600 mm
> 7601 mm
In the position range 0...20 mm, the specified linearity limit can be
1)
exceeded by ±100 µm.
Nominal length = 500 mm, magnet in the middle of the measuring range
2)
For
: Indoor use and use up to 2000 m above sea level.
3)
Individual specifications as per Balluff factory standard, resonant
4)
frequencies excluded
For
: The transducer must be externally connected via a limited-
5)
energy circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1, or a class 2 power supply as defined in UL 1310 or
UL 1585.
10...30 V DC
≤ 0.5 V
SS
≤ 140 mA up to 1524 mm
≤ 180 mA from 1525 mm
≤ 500 mA
Up to 36 V
Up to 36 V
500 V AC
Signal cable to GND
36.8 mm
50...7620 mm
Approx. 1.4 kg/m
Aluminum
max
1160 Hz
1010 Hz
805 Hz
490 Hz
245 Hz
180 Hz
170 Hz