Télécharger Imprimer la page

Balluff BTL7-V50D-M0500-P-C003 Notice D'utilisation page 29

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 41
BTL7-V50D-M _ _ _ _ -P-C003
Transducer in a Profile Housing
4
Installation and connection (continued)
4.3
Floating magnets
The following must be observed when installing the
magnet:
To ensure the accuracy of the position measuring
system, the magnet is attached to the moving member
of the machine using non-magnetizable screws
(stainless steel, brass, aluminum).
The moving member must guide the magnet on a track
parallel to the transducer.
Ensure that the distance A between parts made of
magnetizable material and the magnet is at least
10 mm (see Figures 4-5 to 4-9).
Maintain the following values for distance B between
the magnet and transducer and for center offset C (see
Figures 4-5 to 4-9):
Type of magnet
BTL5-P-3800-2
0.1 to 4 mm
BTL5-P-5500-2
5 to 15 mm
BTL5-P-4500-1
0.1 to 2 mm
BTL6-A-3800-2
4 to 8 mm
BTL6-A-3801-2
4 to 8 mm
The selected distance must stay constant over the entire measuring
1)
length.
For optimum measurement results, a distance B of 6 to 8 mm is
2)
recommended.
Tab. 4-2:
Distance and offset for floating magnets
A
A
Fig. 4-5:
Dimensions and distances with BTL5-P-3800-2 magnet
A
A
Fig. 4-6:
Dimensions and distances with BTL5-P-5500-2 magnet
www.balluff.com
Distance B
Offset C
1)
± 2 mm
± 15 mm
± 2 mm
± 5 mm
2)
± 5 mm
2)
C
C
A
A
Fig. 4-7:
Dimensions and distances with BTL6-A-3800-2 magnet
A
A
Fig. 4-8:
Dimensions and distances with BTL6-A-3801-2 magnet
Plug with
A
A
LED
4
Fig. 4-9:
Dimensions and distances with BTL5-P-4500-1
electromagnet (24 V/100 mA)
The measuring range is offset by 4 mm towards
the transducer plug (see Figure 4-9).
C
C
C
english
9

Publicité

loading

Ce manuel est également adapté pour:

Btl7-v50d-m p-c003 serie