Télécharger Imprimer la page

SAER Elettropompe NCB Serie Manuel D'emploi Et D'entretien page 27

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 40
- Translation of the original instructions
alignment of the complete set;
the gaskets conditions: there must be no leakages;
alignment of the complete set;
performances of the pump (flow / head);
motor data (current consumption, value and imbalance of voltages, isolation, vibrations, etc. ...): refer to motor instruction;
the condition of all electrical connections (terminal, grounding, control panel, etc. ...);
Record data and keep them for future reference.
WARNING!
Perform measurements with appropriate instruments.
7.3 OPERATIONS NEEDED EVERY 3000 WORKING HOURS
Check:
The conditions of the shaft protections: wear rings and bushings;
The conditions of the shaft;
The conditions of the impeller.
If necessary, replace the components listed above.
7.4 LUBRICATING THE BEARINGS
Il tipo dei cuscinetti è riportato nella documentazione tecnica di riferimento.
Pumps with the bearings permanently lubricated with grease 8version supplied a standard): the bearings are of the permanently
lubricated type (with grease) and they do not request any maintenance. The intervals of the indicative changing are indicated in the TAB.IV
(foreseen duration according to L
Pumps with oil bath bearing (version supplied upon request)
Pumps with bearings in oil bath are shipped without oil inside. Before starting, the pump must be plugged with the lubricatingoil in
WARNING!
the bearing support.
Use a costant level oiler (supplied on request).
WARNING!
Replenish and top up the oil, through the oiler.
WARNING!
It is oil supplier's responsibility to indicate an oil with suitable characteristics.
Do not mix different types of oil.
WARNING!
Do not introduce contaminating substances inside the bearing, the support and in the oil.
Characteristics of the oil to be used for the normal working conditions (Tamb.= -10°C – 40°C, Tmax bearings = 110°C) - the following indications are of
general character, for some applications may be necessary oils with higher performance
-
Basic oil: mineral (suggested) or synthetic
-
Viscosity Index– VI min: 95
-
Min. Viscosity Grade ISO VG: 100
-
Working temperature: -10°C / + 170°C
-
Flash point > 200°C
Some types of the oil that are possible to be used
-
AGIP ARUM HT
The relubrication breaks has to be based on the type of use. Approximately every 1000 - 1500 working hours and not less than once a year.
7.5 PUMP DISASSEMBLY
Refer to specific literature, and require it to the manufacturer (section, instructions etc ...)
Execute the pump stop as indicated above.
Before executing any operation, turn off the power and prevent it from being reconnected. Assure that the pump cannot be started
accidentally.
Follow all safety rules, listed in the previous paragraphs and those, pertaining the country where it operates.
The rotating part of the pump, can be removed without removing the pump body from the piping.
Dismantling procedure: see Annex A
Keep the manual for future reference - For more informations visit www.saerelettropompe.com
).
10
Oil filling procedure
Pour the oil from the cap (1)- Chek that the level arrive to the middle of the control window (red
dot - 4) – This is the necessary quantity of oil for pump operation.
Open the oiler (2) and pour the oil in the overtuned bulb.
Once the bulb (4) is returned to its position, the quantity of oil must be such that, its level in the
oiler is about at the center line of the bearing (3).
This is the level in the oiler only and constitutes the oil reservoir which progressively over time is
consumed.