BML SF2-I2 _ _ -GZZZ - ZZZ5-...
Incremental Magnetic Encoder System
4
Installation and connection (continued)
Pin Assignments
The sensor with analog interface
(BML SF2-_ _ _ _-G...) includes reverse-polarity
protection and miswiring protection.
Pin
Wire color
Electrical Connection
BML SF2-...
...-S284 ...-KA
...-KF
1
WH
WH
2
BN
BN
3
GN
GN
4
YE
YE
5
GY
GY
6
PK
PK
7
BU
BU
8
RD
RD
9
BK
–
10
VT
–
11
GY-PK
–
1)
12
RD-BU
–
1)
Shield
TR
TR
As delivered, the wire is not fed through.
1)
Tab. 4-7:
Connection assignment BML SF2-...-KA/KD/KF and
BML SF2-...-S284
www.balluff.com
Analog interface Sin/Cos (1Vpp)
BML SF2-_ _ _ _-G...
No reference
Single signal or
signal
fixed-periodic
...-KD
...0_-G...
WH
BN
GN
YE
GY
Must remain
free
PK
BU
RD
BK
VT
TR
Must remain free
1)
OR
Must remain free
1)
TR
Signal
Pole-periodic
reference signal
...1_-G...
...2_-G...
−B (−Cos)
+B (+Cos)
+A (+Sin)
−A (−Sin)
+Z
–Z
GND
+5 V DC
GND sense
V DC sense
Shield
Description
Sinusoidal analog signal
Sinusoidal analog signal
Sinusoidal analog signal
Sinusoidal analog signal
Reference signal
Sensor head ground (0 V)
Operating voltage
GND sense
V DC sense
(Connector housing to) shield
english
17