Cleaning
Always disconnect the appliance from the power outlet and
•
let it cool before cleaning. Never immerse the appliance in
water to prevent electric shocks.
Wipe over the exterior of the appliance with a soft wet cloth
•
and neutral detergent and then wipe dry with a dry cloth.
Do not use gasoline or other chemicals to clean the unit.
•
Clean the dust filter once every two weeks. Clean the dust
•
filter with neutral detergent and about 40°C water. Rinse off
any detergent, then let it air-dry before inserting it back into
the unit (pic.6).
•
If you do not use the unit for a longer time, empty the water
tank completely. Make sure that the unit is disconnected
from the power supply and that it is clean. Keep the unit
covered in a dry place.
Troubleshooting
Problem
1. Unit does not start
when pressing
"POWER".
2. It's not cool
enough.
3. Unit is too loud.
4. E1 Code
5. E2 Code
6. Compressor does
not start
Possible causes
Water tank is full and indicating light
"W.F." is blinking.
Room temperature is lower than the set
temperature during operation mode
cooling.
The ambient temperature is too low or
too high.
In dehumidification mode, the ambient
temperature is too low.
Doors or windows are not closed.
There are heat sources in the room.
Exhaust hose is not installed or blocked.
Set temperature is too high.
Air inlet is blocked.
The ground is not even and flat enough
The sound comes from the flowing of
the refrigerant inside the unit.
Room temperature sensor is not
functioning.
The hose temperature sensor doesn't
work.
Thermal protection function is activated.
Pic.6
Suggestions
Empty the water tank.
Reset the temperature.
We recommend the operaiton at 7-35°C.
The ambient temperature needs to be
higher than 17°C.
Close all doors and windows.
Remove the heat sources if possible.
Install the exhaust hose and make sure
that the hose is clean and not blocked by
any objects.
Reset the temperature.
Clean the air inlet
Place the unit on an even and flat surface.
None, this sound is normal.
Let the sensor be replaced.
Let the sensor be replaced.
Please turn off the device and restart it 3
minutes later.