Hole
BGs
COIN SLIDE OPTION
This option is either SELECTED "ON" or NOT SELECTED "OFF."
Replacement of metercase will be needed for coin slide mounting.
aad
Not Selected "OFF"
ars
Selected "ON."
NOTE: This option needs to be set to "00" unless the
metercase has been changed to accept a coin slide device.
Press DELICATES button 3 consecutive times for this
selection. When coin slide mode is selected, set "b." equal to
value of slide in coins. Set "6 xx" (REGULAR CYCLE PRICE)
and "3.xx" (SPECIAL CYCLE PRICE) to number of slide
operations. 6 01 & 3.01 =1 slide push.
NOTE: If the installer sets up "CS" on a coin drop model,
it will not register coins.
~» Press PERM. PRESS button once to advance to next code.
j
ADD COINS OPTION
This option is either SELECTED "ON" or NOT SELECTED "OFF."
This option causes the customer display to show the number
of coins (coin 1) to enter, rather than the amount.
Eff] | Not Selected "OFF"
If cycle counter (9 OC) is selected, the following is true:
100
Represents the number of cycles in HUNDREDS.
1 02 = 200
200
Represents the number of cycles in ONES.
225=
25
TOTAL CYCLES = 225
This is "VIEW ONLY" and cannot be cleared.
Press the PERM. PRESS button once to advance
to next code.
lf money counter (1.0C or 1.CO) is selected, the following is true:
3 00 Currency amount in HUNDREDS.
3 01 = 100.00
400
Currency amount in ONES.
468=
68.00
5 00 Currency amount in HOUNDREDTHS.
575=
00.75
TOTAL = 168.75
END OF SET-UP PROCEDURES
Selected "ON."
Press DELICATES button 3 consecutive times for this selection.
PN MODELS: This option is not selectable.
~» Press PERM. PRESS button once to advance to next code.
ti ct | COIN/DEBIT OPTION
WL
Both coin and debit selected. (NOT AVAILABLE)
ib
Coins selected, debit disabled.
Press DELICATES button 3 consecutive times for this selection.
uf Wo
Debit Card selected, coin disabled. Default for PN models,
and for PN operation, must be set as J._d.
Press DELICATES button 3 consecutive times for this selection.
iFa
Enhanced Debit is self-selected when a Generation 2 card
—
reader is installed in the dryer. The "Ed" option cannot be
manually selected or deselected. (NOT AVAILABLE}
Press PERM. PRESS button once to advance to next code.
aly
Lag
PRICE SUPPRESSION OPTION
This option is either SELECTED "ON" OR NOT SELECTED
"OFF." This option causes the customer display to show
"AVAILABLE" or "ADD" rather than the amount of money
to add. (Used mainly in debit installations.)
L.fiff | Not Selected "OFF."
L FS
Selected "ON." Press DELICATES button once for this selection.
~» Press PERM. PRESS button once to advance to next code.
CLEAR ESCROW OPTION
PLE
~~
This option is either SELECTED "ON" OR NOT SELECTED
"OFF." When selected, money held in escrow for 30 minutes
without further escrow or cycle activity will be cleared.
mLeé, | Selected "ON."
nf
Not Selected "OFF." Press DELICATES button once to deselect
this option.
~» Press PERM. PRESS button once to advance to next code.
iifif? | HUNDREDTH INCREMENT OFFSET
wag
This represents the hundredth increment price offset used
in Generation 2 (Enhanced Debit) PN models set up with card
reader. Choose from 0-4 hundredths by pressing the WHITES
AND COLORS button. (NOT AVAILABLE)
~> Press PERM. PRESS button once to advance to next code.
16
EXIT FROM
SET-UP
MODE
@ PD MODELS:
Reinstall access door.
@ PN MODELS where AA1 plug was removed:
4. Unplug dryer or disconnect power.
2. Open console, reinsert jumper into AA1, close console.
3. Plug in dryer or reconnect power.
@ PN WITH PROGRAMMING SWITCH: Turn key clockwise and
remove.
@ If Service Access Code was used to enter set-up mode: From
Set-up Code 8, press button #1 for 4 seconds, wait 2 minutes
without touching any buttons (without diagnostic modes running),
or power down the dryer, then reapply power.
<=
Whitlpdéol
Europe
EU - DECLARATION
OF CONFORMITY
CE - DECLARATION DE CONFORMITE
WE (rousy> BAUKNECHT
HAUSGERATE
GmbH, D-73614 Schorndorf
representing (représentanti: WHIRLPOOL EUROPE
S.r.1
1-21025 COMERIO
deelal
déclaror
y that the product
ThUé que le produit
MDG25PD
MDG25PN
dryer
Maytag
(séeche linge}
Maytag
to which this declaration relates is in conformity with the following standard(s) or other
EN 60335¢1 :2002+AI+A2+ALI+AI2+A13+A14
EN 60335-2-11:20034+AT+A2+ATL
EN 12752«1:1999
EN 62233:2008
EN ISO 10472-1:2008
EN ESQ 10472-2:2008
EN 58614-1;2006+A1 :2609
EN 55014=2:1997+Corrigendum :1997+A1 :2001+A2 :2008
EN 61000-3-12:2005
EN 61000-3-11:2000
following the provisions of Directive(s):
suivant les prévisions des Directives
2006/42/EC MACHINERY DIRECTIVE (CzE dire
2009/142/EC EUROPEAN GAS APPLIANCE
E
ELECTROMAGNETIC COMPATIBILITY DIRECTIVE (CEE Directive Comparihitié
i)
OHS DIRECTIVE (ce,
2002/96/EC WEEE DIRECTIVE (cz
¢ RoftS)
represented by
Schorndorf, 18.10.2011
Franz Hartmann
Karl-Dieter Klingenstein
Place and date:
Director PDC FC EMEA
Product Approval
Hiew et date:
GPO, Schorndorf