Télécharger Imprimer la page

Ooni UUP19E00 Manuel D'instructions page 12

Publicité

Les langues disponibles

Les langues disponibles

Product technical information
Model number
BG07-100A (Ooni Koda 16)
Product Label
• Do not store spare LP-gas cylinder under or near the appliance.
• Never fill the cylinder beyond 80 percent full.
• If the information beyond is not followed exactly, a fire causing death or serious injury
may occur.
• Minimal clearance from sides and back of the unit to combustible construction, 24 inches
from the sides and 24 inches from the front.
• Do not use the appliance under overhead combustible surfaces.
• CAUTION: For use with a gas appliance regulator. The
regulator supplied must be used with this appliance..
This regulator is set for an outlet pressure of 11 iwc.
• Turn o the LP supply at cylinder when appliance is not
in use.
• This appliance is not intended for commercial use.
• The instruction manual contains important information
necessary for the proper assembly and safe use of the
appliance.
• Read and follow all warnings and instructions before
assembling and using the appliance.
• Follow all warnings and instructions when using the
appliance.
• If instruction or parts are missing contact
support.ooni.com
Ooni Limited, Unit 5, Bishopsgate Business Centre,
189 West Main Street, Broxburn, UK, EH52 5LH
202001000001
Always route the gas hose away from the oven. The hose must not touch the oven body.
WARNING Hose pipe can be a tripping hazard
Hose pipe can be a tripping hazard
Coloca siempre el tubo flexible de gas alejado del horno. El tubo flexible no debe tocar el
cuerpo del horno.
ADVERTENCIA El tubo flexible puede generar riesgo de tropiezos
Éloignez toujours le tuyau à gaz du four. Le tuyau ne doit pas toucher à la structure du four.
MISE EN GARDE Le tuyau peut présenter un risque de trébuchement
24"
35.4"
12
ANS Z21.89-2017 CSA 1.18-2017 Outdoor Cooking
Specialty Gas Appliance. For outdoor use only. If
stored indoors, detach and leave cylinder
outdoors.
Manufacturer: Ooni Limited
Model: Ooni Koda 16
LIGHTING INSTRUCTION - TO LIGHT THE
BURNER
Read all instructions before lighting
•Make sure the control knob is in OFF position,
and then turn the liquid propane cylinder
valve ON by slowly turning counterclockwise.
•Push in and slowly turn the control
knob anticlockwise until you hear a
click and the burner ignites.
• If burner doesn't light within 5
seconds, turn the knob OFF, wait 5
minutes and repeat the lighting.
Components
Main Burner
Fabricante: Ooni Limited
Modelo: Ooni Koda 16
Ooni Limited, Unit 5, Bishopsgate Business Centre,
189 West Main Street, Broxburn, Reino Unido, EH52 5LH
• No almacenes la bombona de gas LP de repuesto debajo o cerca del aparato.
• Nunca llenes la bombona más del 80%.
• Si no se siguen al pie de la letra las indicaciones anteriores, puede producirse un
incendio que cause la muerte o lesiones graves.
• La distancia mínima entre los laterales y la parte trasera de la unidad a la construcción
combustible debe ser de 24 pulgadas por los lados y 24 pulgadas desde la parte
delantera.
• No utilices el aparato debajo de superficies elevadas que sean combustibles.
• PRECAUCIÓN: Para usar con un regulador para aparatos de gas. Este aparato debe
utilizarse con el regulador suministrado. El regulador está configurado para una
presión de salida de 11 iwc.
• Cierra el suministro de LP en la bombona cuando el aparato no esté en uso.
•Este aparato no está diseñado para uso comercial.
• El manual de instrucciones contiene información importante necesaria para el
montaje correcto y el uso seguro del aparato.
• Lee y sigue todas las advertencias e instrucciones antes de montar y utilizar el aparato.
• Sigue todas las advertencias e instrucciones cuando utilices el aparato.
• Si faltan instrucciones o piezas, ponte en contacto con support.ooni.com
Rate Input
PA-A00034
Propane
(BTU/H)
Orifice Size
1.11mm
29000

Publicité

loading

Ce manuel est également adapté pour:

Koda 16Uup0ab00