Installation and Operating Instructions
EN
Product name
AIR1-JVK XH 3500-4500/RH 3000
AIR1-JVK XH 5500/RH 5000-6000
AIR1-JVK XH 7000/RH 8000
AIR1-JVK XH 8500/RH 9500
AIR1-JVK RH 12000
AIR1-JVK RH 15000
CHAPTER 2
INSTALLATION AND
COMMISSIONING
m
WARNING
nmlr
m
WARNING
Multi-leaf damper AIR1-JVK
Weight
(kg)
5
6.6
7.8
8.6
10
13
Dimensions Multi-leaf damper for AIR1 XC / XVP units
Type
AIR1-JVK XC 500
AIR1-JVK XC 700
Art.-Nr. Type
AIR1-JVK XC 1400
AIR1-JVK XC 2200/XVP 2500
AIR1-JVK XC 3200/XVP 3500
2�1 General installation instructions
m
Risk of personal injury and material damage!
Internal sheet metal parts have sharp edges and notches that can cause scratches/injuries during installation
and maintenance of the unit and/or accessories�
– The installation and maintenance of the unit may only be carried out by qualified specialist personnel.
– Suitable protective equipment must be worn.
2�1�1 Receipt
Please check delivery immediately on receipt for accuracy and damage. If damaged, please notify the carrier immedia-
tely. In case of delayed notification, any possible claim may be void.
2�1�2 Storage
When storing for a prolonged time, the following steps are to be taken to avoid damaging influences:
Protection by dry, airtight and dust-proof packaging (plastic bag with desiccant and humidity indicators). The storage
place must be waterproof, vibration-free and free of temperature variations. Damages due to improper transportation,
storage or commissioning must be verified and are not liable for warranty.
2�1�3 Disassembly and re-assembly
m
Risk of personal injury and material damage!
The disassembly and re-assembly of the unit are not part of routine maintenance.
– The disassembly and re-assembly of the unit may only be carried out by a qualified specialist.
Runtime
Ambient
Power
(open/closed)
temp� (°C)
max� (W)
(s)
40...75
-30 - 50
2.5
40...75
-30 - 50
2.5
40...75
-30 - 50
2.5
40...75
-30 - 50
2.5
40...75
-30 - 50
2.5
40...75
-30 - 50
2.5
R
T
A
D
A
B
340
185
440
235
A
540
285
540
335
740
435
3
Operating
Protection
voltage (W)
class (IP)
24 DC
24 DC
24 DC
24 DC
24 DC
24 DC
D
R
S
423
320
170
523
420
220
B
D
R
S
623
520
270
623
520
320
823
720
420
Actuator type
Spring return
Spring return
Spring return
Spring return
Spring return
Spring return
Fig�1
T
U
300
100
400
150
T
U
500
200
500
250
700
350

Publicité