Télécharger Imprimer la page

SIKA VMI Serie Notice D'utilisation page 27

Publicité

Les langues disponibles

Les langues disponibles

®
induQ
- Series VMI
3
Construction and function
Components:
Housing:
The housing consists of aluminium die cast-
ing and has the IP65 degree of protection.
Electrical connection:
The electrical connection is made via 5-pin
plug M12x1.
Operation / flow indicator LED.
Process connection:
The process connections are available in dif-
ferent sizes.
Type plate (sticker).
Construction:
The measuring tube with its earthing sleeves and electrodes passes
through the housing and forms the external process connection of the
VMI.
A magnetic field for the measurement process is generated inside the
sensor housing, which also contains the sensor and signal condition-
ing circuitry.
The two stainless steel electrodes are located in the middle of the
measuring tube between the earthing sleeves.
The VMI does not need any moving parts to make measurements. The inside of the measur-
ing tube is completely open, allowing the fluid to flow unhindered through the measuring
tube.
Function:
The magnetic inductive flow sensor operates in accordance with the principle of induction,
i.e. a DC voltage is generated by the movement of a conductor in a magnetic field:
The measuring tube of the VMI is located in a magnetic
field (B).
An electrically conductive liquid (Q) flows through the
measuring tube. The positive and negative charge car-
riers are deflected in opposite directions.
A voltage perpendicular to the magnet field is generat-
ed and picked up by the two electrodes.
The resulting induced voltage is proportional to the
mean flow velocity of the liquid.
The electronics of the VMI converts the induced voltage to a flow-proportional frequency sig-
nal.
Technical changes reserved
Construction and function
- 27 -

Publicité

loading

Ce manuel est également adapté pour:

Vmi 07Vmi 10Vmi 20