Installation instructions, for professionals only
Remote start
With the function selection switch 7 the start of sauna/evaporator operation or
user program 1/2 can be selected.
● The function selection switch 7 is set to the OFF position as standard. The start
of sauna/evaporation operation is activated. Terminal "S" starts the sauna
operation and terminal "C" starts the evaporator operation.
● If you wish to activate user program 1/2, place the function selection switch
7 in the ON position. Terminal "S" starts user program 1 and terminal "C"
starts user program 2.
Connection: see "5.12. Remote start" on page 31
Temperature/humidity display (actual/set value)
Using function selection switch 8 you can select whether the actual value (tem-
perature, humidity) is displayed or the set level continues to be displayed after
entering the setting.
● The function selection switch 8 is set to the OFF position as standard. The dis-
play of the actual values is activated.
● If you wish to activate the set values, place the function selection switch 8 in
the ON position.