EAS ELECTRIC EMIH320-3FL Guide D'utilisation page 58

Publicité

Les langues disponibles

Les langues disponibles

High temperature of ceramic
E3
plate sensor.(1#)
High temperature of ceramic
E4
plate sensor.(2#)
High temperature of
E5
IGBT. (1#)
High temperature of
E6
IGBT. (2#)
Ceramic plate temperature sensor
failure- -short circuit. (F3 for
F3/F6
1#,F6 for2#)
Ceramic plate temperature sensor
failure--open circuit. (F4 for
F4/F7
1#,F7 for2#)
Ceramic plate temperature sensor
failure—invalid. (F5 for 1#,F8
F5/F8
for2#)
Temperature sensor of the IGBT
failure. (short circuit/open circuit
F9/FA
for #1)
Temperature sensor of the IGBT
FC /FD
failure. (short circuit/open
circuit for #2)
2) Specific Failure & Solution
Failure
The
LED does
not
come
on
when
unit
plugged in.
No Auto-Recovery
Problem
No power supply
is
Accessorial power
board and display
board connection
failure
The accessorial
power board is
damaged.
The display
board
is
damaged.
Wait for the temperature of
ceramic plate return to normal.
Touch "ON/OFF" button to
restart unit.
Wait for the temperature of IGBT
return to normal. Touch "ON/OFF"
button to restart unit.
Check whether the fan runs
smoothly; if not , replace the fan.
Check the connection or
replace the ceramic plate
temperature sensor.
Replace the power
board.
Solution A
Check to see if plug
is secured tightly in
outlet and that
outlet is working.
Check the
connection
Replace the
accessorial power
board.
Replace the
display board.
24