Photocells 1
H
function
Photocells 2
J
function
L
Stop command
Remote control
P
function
F3 function settings (function 3-1) :
Gate's position
Closed
Open
Stop during moving
Closing
Opening
D3- Testing and checking
Make sure the general safety precaution «WARNING» has been carefully observed :
• Release the gearmotor with the proper release key.
• Make sure the gate can be moved manually during opening and closing phases with a force of max
390N (40 kg approx).
• Lock the gearmotor.
• Using the key selector switch, push button device or the radio transmitter, test the opening, closing and stopping
of the gate and make sure the gate is in the intended direction.
• Check the devices one by one (photocells, blinker, key selector, etc.) and confirm the control unit recognizes
each device.
D4- Recognition of LED
LED indications
LED 1 Photocells
LED 2 Photocells
EN
36
H-0
H-1
J-0
J-1
L-0
L-1
P-1
P-2
The reaction of photocells when detecting obstacles
No effect
Reloads automatic closing time
Reloads automatic closing time
Open
No effect
Descriptions
The LED1 turns on, when there is an obstacle between the photocells or an aligning
defect or a connection defect (Be carefull, function H must be activated with a connected
photocell on PH1).
The LED2 turns on, when there is an obstacle between the photocells or an aligning
defect or a connection defect (Be carefull, function J must be activated with a connected
photocell on PH2).
Stand-by
Ready
Stand-by
Ready
Close
Open
Close
Open
Photocells
Photocellule 1
The factory setting is « H-0 »
The factory setting is « J-0 »
The factory setting is « L-0 »
Exit 11 and 12
The factory setting is « P-1 »